Serial number ...........................
Built-in hobs
Only use the built-in hobs after you
assemble the hob into correct built-in units
and work surfaces that align to the
standards.
Connection cable
The hob is supplied with the connection
cable.
Replace the damaged mains cable only
with the spare parts cable. Speak to
your local Authorised Service Center.
WARNING! All electrical
connections must be made by
a qualified electrician.
CAUTION! Do not drill or
solder the wire ends. This is
strictly forbidden!
CAUTION! Do not connect the
cable without cable end sleeve.
Two-phase connection
1. Remove the cable end sleeve from
black and brown wires.
2. Remove an insulation of the brown
and black cable ends.
3. Apply a new wire end sleeve of 1.5
mm² on each cable end. (special tool
required).
Cable cross section
N
L1
N
L
230V~ 400V 2~N
L2
One-phase connection - 230 V~ Two-phase connection - 400 V 2 ~ N
Green - yellow Green - yellow
N Blue and blue Blue and blue N
L Black and brown Black L1
Brown L2
18