EasyManua.ls Logo

Smith-Root GPP 2.5 - Page 10

Smith-Root GPP 2.5
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
GPP ELECTROFISHER
www.smith-root.com
The average current limits for Warning and Error can be found in the following chart:
2.5 GPP
Frequency 60/120 CPS 60 CPS 30 CPS 15 CPS 7.5 CPS
50-500 V
High Current Warning 5.8 3.4 2.0 1.3 0.8
High Current Error 7.2 4.3 2.6 1.6 1.0
50-1000V
High Current Warning 3.0 1.8 1.0 0.6 0.4
High Current Error 3.7 2.2 1.3 0.8 0.5
5.0 GPP
Frequency 60/120 CPS 60 CPS 30 CPS 15 CPS 7.5 CPS
50-500 V
High Current Warning 11.3 6.8 4.0 2.5 1.5
High Current Error 14.2 8.5 5.1 3.1 1.9
50-1000V
High Current Warning 6.4 3.8 3.4 1.3 0.8
High Current Error 8.0 4.8 4.3 1.7 1.0
7.5 GPP
Frequency 60/120 CPS 60 CPS 30 CPS 15 CPS 7.5 CPS
120/170 High Current Warning 50.0 30.0 18.0 10.8 6.5
High Current Error 62.5 37.5 22.5 13.5 8.1
240/340 High Current Warning 25.0 15.0 9.0 5.4 3.3
High Current Error 31.1 18.8 11.3 6.8 4.1
360/500 High Current Warning 16.6 10.0 6.0 3.6 2.1
High Current Error 20.8 12.5 7. 5 4.5 2.7
720/1000 High Current Warning 8.3 5.0 3.0 1.8 1.1
High Current Error 10.4 6.3 3.8 2.3 1.4
9.0 GPP
Frequency 60/120 CPS 60 CPS 30 CPS 15 CPS 7.5 CPS
60/85
High Current Warning 120.0 72.0 43.0 26.0 15.5
High Current Error 150.0 90.0 54.0 32.4 19.5
120/170
High Current Warning 60.0 36.0 21.5 13.0 7.8
High Current Error 75.0 45.0 27.0 16.2 9.7
240/340
High Current Warning 30.0 18.0 11.0 6.5 4.0
High Current Error 37.5 22.5 13.5 8.1 4.9
480/680
High Current Warning 15.0 9.0 5.5 3.3 2.0
High Current Error 18.8 11.3 6.8 4.1 2.5
OPERATING LIMITS