EasyManua.ls Logo

Smiths detection HI-SCAN 100T100T-2is User Manual

Smiths detection HI-SCAN 100T100T-2is
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Conventional X-ray Inspection Units HI-SCAN
with HiTraX Electronics
User's guide for users with
supervisor access level
All rights reserved!
The reproduction, transmission or use of this document or its contents
is not permitted without express written authority. Offenders will be
liable for damages.
All rights, including rights created by patent grant or registration of a
utility model or design, are reserved. Modifications reserved.
95584681 01/01/09 © Smiths Heimann
SMITHS HEIMANN
www.smithsdetection.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Smiths detection HI-SCAN 100T100T-2is and is the answer not in the manual?

Smiths detection HI-SCAN 100T100T-2is Specifications

General IconGeneral
X-ray generator160 kV
Wire resolution38 AWG
Conveyor speed0.2 m/s
TypeDual view X-ray inspection system
Tunnel Dimensions1000 mm x 1000 mm
Max. object size1000 mm (W) x 1000 mm (H)
Power Supply230 VAC ±10%, 50/60 Hz
Operating Temperature0°C - 40°C
Detection TechnologyDual-energy X-ray
ApplicationInspection of baggage and freight

Summary

Guide for Users with Operator Access Level

How to Ensure Safety

Essential safety instructions and warnings for operating the X-ray unit.

Here You Find Controls and Indicators

Overview of the physical controls, buttons, and indicators on the X-ray unit.

How to Start and Terminate Your Work

Procedures for initiating and concluding operations with the X-ray unit.

How to Clear the Tunnel and the Conveyors

Instructions for removing objects and cleaning the inspection tunnel.

How to Log Out

Steps for securely exiting the system and logging out.

How to Switch Off

Procedure for safely shutting down the X-ray unit.

How to Ensure Safety

Warning Signs Used in the Safety Instructions

Explanation of various warning symbols and their meanings in safety instructions.

Warning Signs Installed on the X-ray Inspection Unit

Identification and meaning of warning signs physically present on the unit.

Comply with All Legal Requirements and Official Conditions of Use

Guidance on adhering to national and international regulations for unit operation.

Pay Attention to the Safety Instructions

Crucial safety guidelines to be followed during operation and maintenance.

How to check the HI-SCAN X-ray unit before switching on

What to Observe When Evaluating X-ray Images

Guidelines for careful and accurate evaluation of X-ray images during inspection.

Here You Find Controls and Indicators

The Emergency Stop Buttons

Further Control Elements

The Separate Emergency Stop Button for Integrated Units*

Description of the emergency stop button for units integrated into a baggage line.

The Hand-Held Bag Code Scanner*

The Keyboard of the HI-SCAN X-ray Unit

4 Function Keys

How to Start and Terminate Your Work

How to Connect the X-ray Unit to the Mains

Procedure for connecting the X-ray unit to the power supply.

How to Switch On

Restart After Emergency Stop

How to Log In

Login via Keyboard

How to Clear the Tunnel and the Conveyors

How to Log Out

Logout via Keyboard

How to Switch Off

How to Carry Out Inspections

How to Place Baggage and Freight Items

Guidelines for correctly positioning baggage and freight on the conveyor.

How to Control the Scanning Process

One-way Mode

Automatic Return Mode*

How to Lead Suspect Items to the Recheck

Mark Suspicious Objects in the X-ray Image*

Procedure for marking suspicious items within the X-ray image.

Mark Scanned Baggage or Freight Item as Suspicious

Method for electronically marking an item as requiring recheck.

Send X-ray Image to Recheck Station(s)*

Send X-ray Image to Central Image Data Archive CIDA*

How to Use the Automatic Detection Functions*

The X-ACT System*

Details on the X-ACT system for automatic detection of suspect objects.

Radioactivity Detector*

The Functions HI-SPOT* and High Density Alert* - HDA

How to Display X-ray Images

The Black and White Image - BW

The HI-MATPLUS System* - The Basic Material Detection*

The Image Displays Organic Only(PLUS)* and Organic Stripping(PLUS)* - O²/O²+/OS/OS+

How to Vary the Absorption Range - VARI

The Image Display with Higher Penetration - HIGH

The Image Display with Lower Penetration - LOW

The Negative Image Display - NEG

The Special Function X-PLORE*

The Image Displays with Superenhancement* - SEN*

The HI-CAT Color- and HI-CAT Black and White Images

The Function VARI-CAT

The Zoom Function

The Function Opti-Zoom*

The Object Finder*

How to Work with the HI-TIPPLUS* and aTIP* System*

Recognized Objects

Procedure for recognizing and marking suspect objects within the TIP system.

Missed Objects

Aborted Projections

How to Work with the OTS Xtrain System*

Training with Feedbacks

Operating the OTS XTrain system with feedback on operator performance.

Recognized Objects

Handling recognized objects within the OTS XTrain training system.

Missed Objects

Procedure for managing missed objects in the OTS XTrain training system.

Aborted Projections

Handling situations where threat projections are aborted in the OTS system.

Training Without Feedbacks

How to Work with the IMS Image Store System*

Store Images

Instructions for storing X-ray images within the IMS system.

How to Lock IMS Functions

Restricting access to storage and recall functions for operator-level users.

How to Operate the Online Recording Functions

Configuring automatic storage of scanned images for archiving.

How to Use the Bag Code Scanner*

Recall and Print* Images

Select a Category/Subcategory

Print Images*

Set Recall Options

How to Work with the Other Functions

How to Correct Operating Troubles

The Configuration Display

Accessing unit configuration data for troubleshooting and diagnostics.

The Error Report

The X-ray Unit Cannot Be Switched On or Switches Off by Itself

How to Reset the Emergency Stop Buttons

The X-ray Unit Switches Off Because of a Power Failure

Error Messages

Messages Without Error Code

Messages in Alphabetical Order

The Image Deteriorates After Some Time of Operation

The X-ACT System* Does Not Work Correctly

Additional Guide for Users with Supervisor Access Level

How to Log In

Steps for supervisor login, including user ID and password management.

How to Set the Login Procedure

Configuration options for user login methods and security settings.

How to Manage User Data

Procedures for managing user accounts, including adding, editing, and deleting.

How to Manage the Access Rights* for Users with Lower Access Level

Defining and assigning access permissions for users with lower security levels.

How to Use the ZIP*, RIDA* and CD/DVD* Drive and the USB Interface*

How to Exchange the Removable Drives*

How to Set the Login Procedure

How to Manage User Data

Select User Entry

Viewing and selecting existing user data entries.

Add New Users

Procedure for creating new user accounts with specific access levels.

Edit User Data

Delete User Data

How to Manage the Access Rights* for Users with Lower Access Level

Standard Management* of Access Rights

Basic configuration of access rights for supervisor-level users.

Access to/Access Rights TIP* and OTS Xtrain* System

Access to/Access Rights Automatic Detection*

Access to User Data

Access to the IMS System* (Without TIP-/OTS Libraries)

Extended Management* of Access Rights

Activating/Deactivating an Access Level

Granting of Access Rights

Particularities Regarding the User Data Management and ISIS Card Programming

How to Transmit User Data* and Access Rights*

How to Manage ISIS Cards*

Programming a Card After Entry of User Data

Steps to program an ISIS card after entering user data.

The Extended ISIS Functions

How to Delete Data from a Card

How to Program a Card

How to Set Operating Options

How to Set the Keys on the Keyboard

Configuration of the keyboard's function and priority keys.

The Priority Keys

The Function Keys

The Image Keys

How to Set Date, Time and Time Zone*

How to Select the Image Settings

How to Enter the Location*

How to Assign the Views to the Monitors*

How to Set the Power Fail Buffer*

How to Set the Scanning Functions

Operating Mode*

The Conveyor Keys

The Function Reverse Scanning*

The Function Continuous Scanning

The Cutless Image Processing

How to Set the Automatic Detection*

HI-SPOT:

Radioactivity Detector:

Message/Conveyor Stop:

Audible Alarm

How to Set the Recheck* or the External Image Evaluation*

Maximum Recheck/Evaluation Time

Transmit Images

Online Recording

How to Use the Extended IMS Functions

Recall and Print* Images

Instructions for recalling and printing stored X-ray images.

Delete, Move and Copy Images

Convert Images*

Rename Images

How to Configure the HI-TIPPLUS* and the aTIP* System

How to Organize HI-TIPPLUS Categories

Structuring threat image libraries into categories and subcategories.

How to Organize HI-TIPPLUS Categories

Add New Categories

How to Import a Threat Image Library*

How to Activate Images

How to Define the Projection Settings

How to Set the Decision Times

How to Work on Reports

How to Activate Feedbacks

How to Display the Object Markings

How to Configure the OTS XTrain System*

How to Organize Training Sessions

Structuring training sessions and organizing basic images within the OTS system.

How to Organize Training Sessions

How to Import an OTS Library*

How to Set the Image Change Frequency

How to Organize Threat Projections

How to Define the Threat Projection Settings

How to Create HI-TIPPLUS and OTS Libraries on Data Carriers

Copy Existing Library from CD or DVD to USB Memory*

Instructions for copying libraries from CD/DVD to USB memory.

Create Own Library

Guidelines for creating custom libraries for import.

Create Own Library

How to Work with TIP* and OTS XTrain* Reports

How to View TIP* and OTS XTrain* Reports

Procedure for accessing and viewing TIP/OTS system reports.

The Meaning of the Report Fields

The Individual Screener Performance Report - Report 2

The Screener Performance Comparison Report - Report 3

The Threat Detection by Category Report - Report 4

How to Download TIP*/OTS XTrain Reports*

Download to ZIP Disk*, CD* or USB Memory*

Steps for downloading reports to external storage media.

Download by Means of Remote Access via Network*

How to Configure the Xport Image Transfer System*

Automatic Transfer

How to Calibrate* the HI-SCAN X-ray Unit

Carry Out Complete Calibration (Fourfold Calibration)

Procedure for performing a comprehensive four-step calibration of the unit.

How to Deactivate/Activate the InLine Interface*/the External Control*

How to Enable the Network Access

How to Generate the Diagnosis Report

How to Set the Print Functions*

Other Operating Troubles

Your Settings

Access Rights

Management of user access rights to menus and functions.

Scanning Functions

Recheck/External Image Evaluation

Automatic Detection

X-ACT:

Activating/deactivating the X-ACT system for automatic threat detection.

IMS Image Store System

TIP Threat Image Projection

OTS XTrain Operator Training System

Threat Projection Settings

Decision Time Settings

Decision Time - Threat Objects

Additional Decision Time - Threat Objects

Decision Time - Combined Threat Images

Additional Decision Time - Combined Threat Images

Feedback to Operators

Display Object Markings

Enable Training System

Printer

InLine - Control and Interface/External Control

Xport Image Transfer System

Related product manuals