Loading...
EEDM596F
Advanced Digital Multimeter
With Color LCD and Bluetooth
®
EEDM596F-Z Rev.
B
(05/19)
13
IP Function
Range: 60 – 12,000 RPM
WARNING!
Keep yourself, clothing, and test equipment
clear of moving parts. Wear safety goggles,
gloves, and protective eyewear around
running engines.
Rotary switch position
Inductive Pick-up connection
COM – “-“ Side of Plug
VHz – “+” Side of Plug
Optional functions
Toggles between 2 or 4 strokes.
Toggles between + or – slope for triggering.
Advances the trigger level.
Activates NR (Noise Reduction, LPF will be
displayed on LCD)
IG Function
RPM: 60 12,000
Pulse Width: 0.2 to 199.9mS
Duty Cycle: 0.0 to 99.9%’
Dwell Angle: 0.0 to 356.4°
Frequency: 1Hz to 1999.9Hz
WARNING!
Keep yourself, clothing, and test equipment
clear of moving parts. Wear safety goggles,
gloves, and protective eyewear around
running engines
Rotary switch position
Selecting the mode
Press this button so the desired function is on the
LCD.
Test lead connection
COM – Black Test Lead0
VHz – Red Test Lead
Optional functions
Toggles between 2 or 4 strokes.
Toggles between + or – slope for triggering.
Advances the trigger level.
Toggles from 1 to 12 cylinders.
Activates NR (Noise Reduction, LPF will be
displayed on LCD)