EasyManua.ls Logo

Snap-On EEDM596F - Current Measurements and Specialized Functions; Low DC and AC Current (µA;mA)

Snap-On EEDM596F
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EEDM596F
Advanced Digital Multimeter
With Color LCD and Bluetooth
®
EEDM596F-Z Rev.
B
(05/19)
10
Measuring Temperature
Range: -40 to 510°C
-40 to 950°F
NOTE:
Temperature measurement requires temperature input
adapter and K-type temperature probe.
CAUTION!
To avoid possible meter or equipment
damage, please note that the optional
thermocouple is rated up to 950°F (510°C).
For higher temperatures, a different probe
is required.
Rotary switch position
Selecting the Temperature Mode
Press the function button until the desired
temperature mode is selected (°F or °C)
Temperature input adapter connection
Optional functions
Activates manual ranging. Hold in for 2 seconds
to return to auto range.
Activates the Min/Max/Ave Record mode.
Hold in for 2 seconds to deactivate.
Toggles between +/- trigger in IP or IG function.
Activates relative mode.
Hold in for 2 seconds to deactivate.
Activates Data Hold on non-automotive
functions. Press again to deactivate.
Hold down for 2 seconds to activate 1mS Peak
Hold on DC volt and DC current functions.
Measuring uA and mA DC
Range: 0.00 – 400 milliamps DC
CAUTION!
Do not attempt to make a current
measurement with the test leads connected
in parallel with circuit to be tested. Test
leads must be connected in series with the
circuit.
WARNING!
Do not attempt to make a current
measurement of circuits with more than
600V present. Instrument damage and/or
personal injury may result.
Rotary switch positions
Up to 400uA Up to 400mA
Test lead connection
COM – Black Test Lead
mAuA – Red Test Lead
Optional functions
Activates manual ranging. Hold in for 2 seconds
to return to auto range.
Activates the Min/Max/Ave Record mode.
Hold in for 2 seconds to deactivate.
Toggles between +/- trigger in IP or IG function.
Activates relative mode.
Hold in for 2 seconds to deactivate.
Activates Data Hold on non-automotive
functions. Press again to deactivate.
Hold down for 2 seconds to activate 1mS Peak
Hold on DC volt and DC current functions.