Measuring Diodes
Range: Approximate Forward Bias Voltage
CAUTION!
Do not attempt to make diode
measurements with circuit energized. The
only way to accurately test a diode is to
remove it completely from the circuit before
attempting to measure it.
Rotary switch position
Selecting the continuity mode
Press this button so the symbol is on the LCD.
Test lead connection
COM – Black Test Lead
VHz – Red Test Lead
1. Connect the black test lead to the banded end of the
diode and the red test lead to the non-banded end
of the diode.
2. Reading on the display should be between 0.3 and
0.8 volts.
3. Reverse test lead connections in 5 above.
4. Reading on the display should be OL (Overload).
NOTE: If diode reads 0 in both directions, diode is shorted.
If diode reads OL in both directions, diode is open.
Optional functions
Activates the Min/Max/Ave Record mode.
Hold in for 2 seconds to deactivate.
Toggles between +/- trigger in IP or IG function.
Activates relative mode.
Hold in for 2 seconds to deactivate.
Measuring Frequency (Hz)
Range: 0.00 – 10MHz
CAUTION!
Do not attempt to make a frequency
measurement if a test lead is plugged in the
A or μmA input jack. Instrument damage
and/or personal injury may result.
WARNING!
Do not attempt to make a frequency
measurement with a voltage source greater
than 600V.
Rotary switch position
Test lead connection
COM – Black Test Lead
VHz – Red Test Lead
Optional functions
Activates manual ranging. Hold in for 2 seconds
to return to auto range.
Activates the Min/Max/Ave Record mode.
Hold in for 2 seconds to deactivate.
Toggles between +/- trigger in IP or IG function.
Activates relative mode.
Hold in for 2 seconds to deactivate.
Activates Data Hold on non-automotive
functions. Press again to deactivate.
Hold down for 2 seconds to activate 1mS Peak
Hold on DC volt and DC current functions.