EEDM596F
Advanced Digital Multimeter
With Color LCD and Bluetooth
EEDM596F-Z Rev.
(05/19)
2
INTRODUCTION
Product Description
The EEDM596F is a hand-held True RMS auto ranging
automotive DMM. The EEDM596F measures ACV, DCV,
ACA, DCA, Resistance, Frequency, Capacitance, Duty Cycle,
Diodes, Continuity, Temperature, RPM, Dwell, and
milli-second pulse width. It also features Bluetooth®
communication for iOS and Android remote reading apps.
CONTENTS
EEDM596F Instrument
Soft Carrying Case -------------------------- EEDM5F-CC
Test Lead Set with Alligator Clips --------- EEDMLEADSET
Inductive Pick-up --------------------------- EEDM512B1
Temperature Input Adapter and Probe ----- EEDMTEMP-1
USB Flash Drive (Manuals) -------------- EEDM596F-USB
Instruction Manual ------------------------- EEDM596F-Z
7 Year Warranty Card
SAFETY
lease follow manufacturers tes
rocedures
whenever possible. Do not attempt to measure
unknown voltages or components until a
complete understanding of the circuit is
obtained.
Read instructions before operating:
Be sure these instructions accompany the tool
when passed from one user to a new or
inexperienced user.
Equipment is used in a manner not specified by
the manufacturer, The protection provided by
the equipment may be impaired.
GENERAL GUIDELINES
ALWAYS
• Test the EEDM596F before using it to make sure it
is operating properly.
• Inspect the test leads before using to make sure
there are no breaks or shorts.
• Double check all connections before testing.
• Have someone check on you periodically if working
alone.
• Have complete understanding of circuit being
measured.
•
Disconnect power to circuit then, connect test leads
to the EEDM596F, then to circuit being measured
.
NEVER
• Attempt to measure unknown high voltages.
• Attempt to measure current with the meter in
parallel to the circuit.
• Connect the test leads to a live circuit before setting
up the instrument.
• Touch any exposed metal part of the test lead
assembly.
INTERNATIONAL SYMBOLS
DANGEROUS VOLTAGE
AC (ALTERNATING CURRENT)
DC (CIRECT CURRENT)
REFER TO INSTRUCTION MANUAL
GROUND
FUSE
DOUBLE INSULATION
SPECIFICATIONS:
IEC 61010-1 Over Voltage:
CAT III – 750Vac/1000Vdc
CAT IV – 600Vac/dc
Pollution Degree 2
E188344 UL61010-1
28DK CAT III 750Vac/1000Vdc
CAT IV 600Vac/dc
DCV
RANGE RES ACCURACY IMPEDANCE
40mV 0.001mV
±(0.1% +5 digits)
10 Meg Ohm
400mV 0.01mV
4V 0.0001V
40V 0.001V
400V 0.01V
1000V 0.1V