Measuring DCV
Range: 0.00 – 1000 Volts DC
CAUTION!
Do not attempt to make a voltage
measurement if a test lead is plugged in the
A or μmA input jack. Instrument damage
and/or personal injury may result.
WARNING!
Do not attempt to make a voltage
measurement of more than 1000V or of a
voltage level that is unknown.
Rotary switch position
Test lead connection
COM – Black Test Lead
VHz – Red Test Lead
Optional functions
Activates manual ranging. Hold in for 2 seconds
to return to auto range.
Activates the Min/Max/Ave Record mode.
Hold in for 2 seconds to deactivate.
Toggles between +/- trigger in IP or IG function.
Activates relative mode.
Hold in for 2 seconds to deactivate.
Activates Data Hold on non-automotive
functions. Press again to deactivate.
Hold down for 2 seconds to activate 1mS Peak
Hold on DC volt and DC current functions.
Activate LPF (Low Pass Filter) on AC or DC volt
functions.
Measuring ACV
Range: 0.00 – 750 Volts AC
CAUTION!
Do not attempt to make a voltage
measurement if a test lead is plugged in the
A or μmA input jack. Instrument damage
and/or personal injury may result.
WARNING!
Do not attempt to make a voltage
measurement of more than 750V or of a
voltage level that is unknown.
Rotary switch position
Selecting the AC mode
Press this button so the AC symbol is on the LCD.
Test lead connection
COM – Black Test Lead
VHz – Red Test Lead
Optional functions
Activates manual ranging. Hold in for 2 seconds
to return to auto range.
Activates the Min/Max/Ave Record mode.
Hold in for 2 seconds to deactivate.
Toggles between +/- trigger in IP or IG function.
Activates relative mode.
Hold in for 2 seconds to deactivate.
Activates Data Hold on non-automotive
functions. Press again to deactivate.
Hold down for 2 seconds to activate 1mS Peak
Hold on DC volt and DC current functions.
Activate LPF (Low Pass Filter) on AC or DC volt
functions.