Page 11 Operation Manual
1.4 FLOOR AND SPACE REQUIREMENTS
1104
Figure 1.3-1
1.5 GENERAL CAUTIONS
A. DURING THE USE AND MAINTENANCE OF THE
MACHINE IT IS MANDATORY TO COMPLY WITH
ALL LAWS AND REGULATIONS FOR ACCIDENT
PREVENTION.
B. THE ELECTRICAL POWER SOURCE MUST HAVE A
GROUND CABLE AND THE GROUND CABLE OF THE
MACHINE MUST BE CONNECTED TO THE GROUND
CABLE OF THE POWER SOURCE.
C. BEFORE ANY MAINTENANCE OR REPAIRS
ARE ACCOMPLISHED THE MACHINE MUST BE
DISCONNECTED FROM THE AIR AND ELECTRICAL
SUPPLY.
D. NEVER WEAR TIES, CHAINS OR OTHER LOOSE
ARTICLES WHEN USING, MAINTAINING OR
REPAIRING THE MACHINE. LONG HAIR IS ALSO
DANGEROUS AND SHOULD BE KEPT UNDER A HAT.
THE USER MUST WEAR PROPER SAFETY ATTIRE -
GLOVES, SAFETY SHOES AND GLASSES.
2.0 INSTALLATION
Your new EEWH311B Air-Electric Tire Changer requires
a simple installation procedure requiring only a few
moments.
Follow these instructions carefully to insure proper and
safe operation.
The Tire Changer is delivered mounted to a wooden skid.
Remove tire changer from its mounts carefully , taking
care to avoid any back strain.
Place Tire Changer where proper operation will be
unobstructed to all sides. Install the machine in a covered
and dry place.
2.0.1 ANCHORING
Once placed in the desired location the tire changer must
be bolted to the f oor.
Secure the machine to the floor through the holes
provided in the cabinet, using 3/8” x 2” anchor bolts
(Recommended).
2.1 ELECTRICAL INSTALLATION
BUILDING ELECTRICAL INSTALLATION MUST BE
MADE BY A LICENSED ELECTRICIAN.
Check that the electrical speci f cations of the power
source are the same as the machine. The machine uses
115V, 60 hz, grounded single phase 20 amp source.
Electric specif cations are clearly marked on a label at
the side of the machine.
FAILURE TO PROVIDE PROPER ELECTRICAL
SUPPLY AND GROUNDING WILL CREATE A SHOCK
HAZARD TO THE OPERATOR.