FJ200 10 Rev. 09/09/14
TROUBLESHOOTING
FOR TECH SERVICE, CALL USA: 877-762-7664, CANADA: 866-824-0524
PROBLEM
POSSIBLE
CAUSE
REMEDY
Jack will not lift or
sustain rated load.
A. Release valve is not
tightened down.
B. Air is trapped in the
hydraulic system.
C. Check ball valve is not
seating properly.
D. Load exceeds the rated
capacityofthejack.
A. Re-insert handle in handle
yoke making sure the
release valve is engaged
by the handle. Rotate
handle clockwise until it
stops. Proceed to pump.
B. Follow step 3 on page 6 of
this manual.
C. Call Tech Service.
D. Use the proper rated
capacityjackforthe
application.
Jack will not lift to full
height.
A. Air is trapped in the
hydraulic system.
B. Not enough hydraulic
uidinreservoir.
A. Follow step 3 on page 6.
B.Removereservoirllplug.
Makesureuidlevelis
equal to top of the internal
cylinder with the lift arm
lowered all the way. See page 9.
Jack will not lower all the
way down without a load.
A.Toomuchuidin
reservoir.
B. Mechanical restriction
somewhere within the
chassis assembly.
C. Bent or deformed
chassis component.
A.Removereservoirllplug.Make
sureuidlevelisequaltotopof
internal cylinder with lift arm
lowered all the way. See page 9.
Removeexcessuidif
above internal cylinder.
B. Follow step 1 under
WEEKLY Maintenance
section of this manual. See page 8.
C. Call Tech Service.
FILL SCREW
FLUID LEVEL
RESERVOIR TUBE
CYLINDER