ADVANCED SETTING cont'd
Spot and pause time (Spot).
This function is blocked when function 3L is activated.
If we select the spot ON time, the Spot Time function
appears on the display screen. When we select this, we
can adjust it from 0.3 to 25 seconds by means of the
adjustment bar. Besides this function, the display screen
also shows Pause Time. If we select this, by means
of the adjustment bar, we can regulate the pause time
between one welding point or section and another. The
pause time varies between 0 (OFF) and 5 seconds.
To access the Spot Time and Pause Time functions,
press the knob
B
for less than 2 seconds. Adjustment
is always made using knob
B
. To conrm, simply
press it for less than 2 seconds. Once the choice has
been conrmed, return is always made to the display
page.
HSA (Automatic Hot Start).
This function is blocked when function 3L is activated.
Once the function has been enabled, the operator may
adjust the starting current (Start Curr) from 10 to 200%
of the welding current (Default 130%). The duration
of this current (S.C. Time) may also be adjusted from
0.1 to 10 seconds (default 0,5 sec.). The switching time
(Slope Time) between the starting current (Start Curr)
and the welding current may also be adjusted from 0.1
to 10 seconds (default 0.5 seconds.).
CRA (crater ller - nal crater lling).
This function is blocked when function 3L is activated.
It is working during welding 2T, 4T and also in
combination with function HSA.
After activating the function, the operator may adjust
the connection time (Slope Time) between the welding
current and the crater lling current (Crater Curr.) from
0.1 to 10 seconds (default 0.5 seconds.).
The operator may also adjust the crater lling current
(Crater Curr.) from 10 to 200% of the welding current
(Default 60%).
The time (C.C. Time) of the crater lling duration may
also be adjusted from 0.1 to 10 seconds (default 0.5
seconds).
Inductance
Adjustment can vary from -9.9 to +9.9. Factory setting
is zero. If the gure is negative, the impedance drops
and the arc becomes harder, while if it increases, the
arc is softer.
To access this function, simply highlight it using the

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Snap-On MIG185i and is the answer not in the manual?

Snap-On MIG185i Specifications

General IconGeneral
BrandSnap-On
ModelMIG185i
CategoryWelding System
LanguageEnglish

Related product manuals