SF2300 Technical Manual
Page 4
Technical Data and Specifications
Model
SF2300 Diesel
Heating Output Level
Super
High
Low
Heating Output Btu/hr (kW/hr)
2.3
(7850)
1.9
(6485)
0.9
(3072)
Fuel consumption L/hr
U.S. Gal/hr)
0.28
(0.07)
0.24
(0.06)
0.1
(0.03)
Fuel type
Diesel
Air flow CFM
49
41
20
Electric power consumption
watts)
12 and 24 V)
34
23
9
Start-up watts12 and 24 V)
≤100 W
Rated voltage
12 or 24 Volt
Voltage lower limit
10.5 Volt or 21 Volt
time-voltage protection: 20sec
Voltage upper limit
16 Volt or 32 Volt
time-voltage protection: 20sec
Overheat Protection
Temperature
115
o
C (239
o
F)
Allowed ambient temperature
40
o
C ~ 76
o
C (-40
o
F ~ 169
o
F)
Weight kg (lb)
2.7 kg (6lb)
Please Note:
Listed technical data is subject to a tolerance of ±10 %
Heater Dimensions