Shenzhen SOFAR SOLAR Co., Ltd.
Solar Grid-tied Inverter
Product Model: SOFAR 3K~6KTLM-G3
User manual

Questions and Answers

  • C
    Cheryl JonesAug 5, 2025
    What to do if Sofar solar 5KTLM-G3 25A Inverter shows GridOVP alarm frequently?
    • P
      Paige HobbsAug 5, 2025
      If the GridOVP alarm occurs occasionally, it could be due to temporary electric grid abnormalities. The inverter should automatically return to normal once the grid stabilizes. However, if the alarm is frequent, verify that the grid voltage and frequency are within the acceptable range. If they are, inspect the AC circuit breaker and AC wiring of the inverter. If the grid voltage/frequency is outside the acceptable range and the AC wiring is correct, contact technical support to adjust the grid over-voltage, under-voltage, over-frequency, and under-frequency protection points, but only after getting approval from your local electrical grid operator.
  • J
    jane36Aug 9, 2025
    How to prevent OverTempDerating on Sofar solar 5KTLM-G3 25A Inverter?
    • V
      Vanessa ManningAug 9, 2025
      To prevent OverTempDerating on your Sofar solar Inverter, ensure it's installed away from direct sunlight. Place it in a cool, well-ventilated area. Also, make sure the inverter is mounted vertically and that the ambient temperature stays below the inverter's maximum temperature limit.
  • B
    bjonesAug 14, 2025
    What to do if Sofar solar Inverter displays GFCI error?
    • D
      Dean MaloneAug 14, 2025
      If your Sofar solar Inverter is showing a GFCI error, switch it OFF and wait for 5 minutes. Then, switch it back ON. If the problem persists, it indicates internal faults of the inverter, and you should contact technical support for assistance.
  • M
    Michelle RobinsonAug 18, 2025
    What to do if Sofar solar Inverter shows BMS OVP error?
    • D
      Deborah ShawAug 18, 2025
      If your Sofar solar Inverter displays a BMS OVP error, close the inverter and lithium battery, wait 5 minutes, and then reopen them. If the problem continues, it may indicate an internal failure of the lithium battery, and you should contact technical support.
  • K
    Karen BurkeAug 22, 2025
    How to fix TempFault_Bat error on Sofar solar 5KTLM-G3 25A?
    • M
      michaelsmithAug 22, 2025
      To resolve a TempFault_Bat error on your Sofar solar Inverter, ensure the unit is not exposed to direct sunlight. Install the inverter in a cool, well-ventilated location, mount it vertically, and verify that the ambient temperature remains below the inverter's temperature limit.
  • M
    Maureen PerezAug 27, 2025
    What to do if Sofar solar 5KTLM-G3 25A displays IsoFault error?
    • J
      Jeff WilsonAug 27, 2025
      If your Sofar solar Inverter is showing an IsoFault error, check the insulation resistance between the photovoltaic array and ground. If you find a short circuit, repair it immediately.
  • M
    Melissa ThomasAug 31, 2025
    How to resolve PvConfigError on Sofar solar 5KTLM-G3 25A Inverter?
    • D
      David RiveraAug 31, 2025
      To resolve a PvConfigError on your Sofar solar Inverter, check the inverter's PV input mode settings (parallel/independent mode). If the settings are incorrect, change the PV input mode accordingly.

Summary

1. Basic safety information

1.1. Safety instructions

Read and understand safety instructions and symbols before installation and troubleshooting.

1.2. Symbols and signs

Explains symbols used in the manual for safety and operational information.

3. Installation

3.6. Installing SOFAR 3 K~6 KTLM-G3

Step-by-step instructions for the physical mounting and securing of the inverter.

4. Electrical Connections

4.2. Connecting PGND Cables

Explains the procedure for grounding the inverter using protection ground (PGND) cables.

4.3. Connecting DC Input Power Cables

Details the process of connecting the DC input power cables to the inverter's terminals.

4.4. Connecting AC Output Power Cables

Guides on how to connect the AC output power cables to the grid or distribution frame.

5. Commissioning of inverter

5.1. Safety inspection before commissioning

Ensures DC and AC voltages are within acceptable ranges before starting the inverter.

5.2. Start inverter

Details the steps to turn on the inverter and indicates correct operation status.

7. Trouble shooting

7.1. Trouble shooting

Provides procedures for identifying and solving common inverter faults and problems.

Sofar solar 5KTLM-G3 25A Specifications

General IconGeneral
Model5KTLM-G3
Rated Power5000 W
Max. DC Input Power7500 W
Number of MPPTs2
Number of DC Inputs per MPPT1
Max. Input Current25A
Max. Input Current per MPPT12.5A
Max. Short Circuit Current15A
Rated AC Output Power5000 W
Max. AC Apparent Power5500VA
Max. Output Current25 A
Rated Grid Voltage230 V
AC Voltage Range180-280V
Rated Grid Frequency50/60Hz
THDi<3%
Max. Efficiency98.2%
Euro Efficiency97.5%
MPPT Efficiency99.9%
DC SwitchYes
Protection DegreeIP65
CoolingNatural Convection
Weight18kg
Operating Temperature Range-25°C to +60°C
CommunicationRS485
Power Factor>0.99 (Adjustable ±0.8)