EasyManua.ls Logo

Sofar solar 20KTLX-G3 - User Manual

Sofar solar 20KTLX-G3
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Shenzhen SOFARSOLAR Co., Ltd.
Solar Grid-tied Inverter
Product Model: SOFAR 15~24KTLX-G3
User manual

Questions and Answers

  • M
    Megan MasonAug 14, 2025
    What causes Reserved (ID113) error on Sofar solar 20KTLX-G3 Inverter?
    • P
      Patricia AndrewsAug 14, 2025
      Check if the ambient temperature of the installation position exceeds the upper limit. If it does, improve ventilation to decrease the temperature. Also, check whether the inverter has dust and whether there are foreign matters blocking the fan at the air inlet.
  • K
    Krista CordovaAug 17, 2025
    What causes CT Disconnect error on Sofar solar 20KTLX-G3 Inverter?
    • N
      nicolejohnsonAug 17, 2025
      Check the wiring of input, output and communication according to the user's manual. If the use method is not ruled out, please contact the new energy customer service of Capital Airlines.
  • D
    Danielle MartinezAug 20, 2025
    What to do if Sofar solar 20KTLX-G3 Inverter GridUVP alarm occurs frequently?
    • C
      chaselloydAug 21, 2025
      If the GridUVP alarm occurs frequently, first check if the grid voltage/frequency is within the acceptable range. If it is not, contact technical support. If the voltage/frequency is ok, check the AC circuit breaker and AC wiring of the inverter.
  • L
    Lauren GarciaAug 25, 2025
    Why does my Sofar solar 20KTLX-G3 Inverter show GridOVP?
    • K
      Kristen MoodyAug 25, 2025
      If the GridOVP alarm occurs occasionally, it is likely due to occasional abnormalities in the electric grid. The inverter will automatically return to normal operation when the electric grid stabilizes.
  • R
    Rachel HenryAug 27, 2025
    What to do if Sofar solar Inverter shows GridOFP repeatedly?
    • C
      Chelsey RobinsonAug 28, 2025
      If the grid voltage/frequency is within the acceptable range and AC wiring is correct, while the GridOFP alarm occurs repeatedly, contact technical support to change the grid over-voltage, under-voltage, over frequency, under-frequency protection points after obtaining approval from the local electrical grid operator.
  • K
    Kimberly HernandezAug 31, 2025
    How to fix FanFault1 on Sofar solar 20KTLX-G3?
    • P
      Patricia MendozaAug 31, 2025
      Check the inverter for dust and foreign objects blocking the fan at the air inlet. If found, improve the ventilation and heat dissipation of the environment.
  • L
    Laura Schwartz DVMSep 3, 2025
    What to do if Sofar solar 20KTLX-G3 Inverter displays OVRT?
    • D
      Donna MartinezSep 3, 2025
      If your Sofar solar Inverter displays OVRT, turn OFF the “DC switch”, wait for 5 minutes, then turn ON the “DC switch”. Check whether the fault is rectified. If not, contact technical support.
  • R
    Richard WhiteSep 6, 2025
    What to do if Sofar solar 20KTLX-G3 Inverter displays unrecoverH wAcOCP?
    • J
      Joseph BergerSep 6, 2025
      If your Sofar solar Inverter displays unrecoverH wAcOCP, turn OFF the “DC switch”, wait for 5 minutes, then turn ON the “DC switch”. Check whether the fault is rectified. If not, contact technical support.
  • E
    Elizabeth CurtisSep 9, 2025
    Why does my Sofar solar Inverter show BusUVP?
    • G
      Gerald ReyesSep 9, 2025
      If the configuration of the PV array is correct, the BusUVP error could be because the sun irradiation is too low. Once sun irradiation returns to normal, the inverter will work normally again.

Summary

Basic Safety Information

Requirement for Installation and Maintenance

Installation must conform to laws, regulations, codes, and standards. Read all instructions before installation.

Symbols and Signs

Explanation of safety instruction symbols used in the manual and on the inverter, including danger, warning, and caution.

Installation

Installation Process

Outlines the step-by-step process for installing the inverter, from preparation to final mounting.

Checking Before Installation

Details checks for outer packing materials and deliverables to ensure correct components are present before installation.

Installation

Provides detailed steps for mounting the inverter, including securing the rear panel and attaching the inverter unit.

Electrical Connection

Electrical Connection

Guides through the process of connecting cables to the inverter, including PGND, DC input, AC output, and communication.

Grounding Connection (PE)

Details the correct procedure for connecting the inverter to the grounding electrode using a ground cable.

Connect Grid Side of Inverter (AC-Output)

Explains how to connect the inverter to the utility grid using the AC power cable, adhering to local grid operator requirements.

Connect PV Side of Inverter (DC-Input)

Provides instructions for connecting the PV array DC input, including DC switch specifications and cable preparation.

Commissioning of Inverter

Trouble shooting and maintenance

Sofar solar 20KTLX-G3 Specifications

General IconGeneral
Rated Output Power20000 W
Max. DC Input Power30000 W
Max. DC Input Voltage1100 V
Start Voltage200V
MPPT Voltage Range200-1000V
Number of MPP Trackers2
Number of DC Inputs per MPPT2
Max. AC Apparent Power22000 VA
Rated Grid Frequency50/60Hz
Grid Frequency Range45-55Hz/55-65Hz
THDi<3%
DC SwitchYes
Protection Class (According to IEC 62109-1)Class I
Protection DegreeIP65
Max Efficiency98.6%
Rated Grid Voltage400 V
Grid Voltage Range310-480 V
Power Factor0.8 leading - 0.8 lagging
Operating Temperature Range-25°C to +60°C
CoolingSmart cooling