  • K
    Kelly WoodAug 19, 2025
    What to do if Sofar solar Inverter shows GridOVP alarm frequently?
    • Z
      Zachary MorrisonAug 20, 2025
      If the GridOVP alarm occurs occasionally, it could be due to temporary electric grid abnormalities. The inverter should automatically return to normal once the grid stabilizes. However, if the alarm is frequent, verify that the grid voltage and frequency are within the acceptable range. If they are, inspect the AC circuit breaker and AC wiring of the inverter. If the grid voltage/frequency is outside the acceptable range and the AC wiring is correct, contact technical support to adjust the grid over-voltage, under-voltage, over-frequency, and under-frequency protection points, but only after getting approval from your local electrical grid operator.
  • W
    wayne10Aug 22, 2025
    How to prevent OverTempDerating on Sofar solar 5KTLM-G3 Inverter?
    • Z
      Zachary Good MDAug 22, 2025
      To prevent OverTempDerating on your Sofar solar Inverter, ensure it's installed away from direct sunlight. Place it in a cool, well-ventilated area. Also, make sure the inverter is mounted vertically and that the ambient temperature stays below the inverter's maximum temperature limit.
  • J
    josephhansenAug 23, 2025
    What to do if Sofar solar Inverter displays GFCI error?
    • S
      Stephen RogersAug 23, 2025
      If your Sofar solar Inverter is showing a GFCI error, switch it OFF and wait for 5 minutes. Then, switch it back ON. If the problem persists, it indicates internal faults of the inverter, and you should contact technical support for assistance.
  • D
    Derrick FloresAug 26, 2025
    What to do if Sofar solar 5KTLM-G3 Inverter shows BMS OVP error?
    • S
      Sarah MccallAug 26, 2025
      If your Sofar solar Inverter displays a BMS OVP error, close the inverter and lithium battery, wait 5 minutes, and then reopen them. If the problem continues, it may indicate an internal failure of the lithium battery, and you should contact technical support.
  • J
    Jason ShafferAug 27, 2025
    How to fix TempFault_Bat error on Sofar solar 5KTLM-G3?
    • D
      Deanna MaldonadoAug 28, 2025
      To resolve a TempFault_Bat error on your Sofar solar Inverter, ensure the unit is not exposed to direct sunlight. Install the inverter in a cool, well-ventilated location, mount it vertically, and verify that the ambient temperature remains below the inverter's temperature limit.
  • K
    Kelli FlynnAug 29, 2025
    What to do if Sofar solar Inverter displays IsoFault error?
    • P
      pinedarichardAug 29, 2025
      If your Sofar solar Inverter is showing an IsoFault error, check the insulation resistance between the photovoltaic array and ground. If you find a short circuit, repair it immediately.
  • J
    Jeffrey StoneAug 31, 2025
    How to resolve PvConfigError on Sofar solar 5KTLM-G3 Inverter?
    • J
      John LawrenceAug 31, 2025
      To resolve a PvConfigError on your Sofar solar Inverter, check the inverter's PV input mode settings (parallel/independent mode). If the settings are incorrect, change the PV input mode accordingly.
  • D
    Danielle JacksonSep 2, 2025
    What to do if Sofar solar Inverter shows GridOVP alarm?
    • K
      Kimberly WelchSep 3, 2025
      If the Sofar solar Inverter alarm 'GridOVP' occurs occasionally, it might be due to an abnormal electric grid. The inverter should automatically return to normal when the grid stabilizes. If the alarm happens frequently, verify that the grid voltage and frequency are within the acceptable range. If they are, inspect the AC circuit breaker and AC wiring of the inverter. If the grid voltage/frequency is not within range and the wiring is correct, and the alarm persists, contact technical support to adjust the grid over-voltage, under-voltage, over-frequency, and under-frequency protection points, but only after getting approval from your local electrical grid operator.
  • E
    Eric MartinSep 5, 2025
    What to do if my Sofar solar 5KTLM-G3 Inverter displays GFCI error?
    • B
      bnelsonSep 5, 2025
      If your Sofar solar Inverter displays a 'GFCI' error, switch the inverter OFF, wait for 5 minutes, and then switch it back ON. If the problem persists, it indicates potential internal faults within the inverter, and you should contact technical support for further assistance.
  • D
    Devin JonesSep 6, 2025
    How to fix OverTempDerating on Sofar solar 5KTLM-G3?
    • M
      Mark AllenSep 7, 2025
      If your Sofar solar Inverter displays 'OverTempDerating', ensure the inverter is not exposed to direct sunlight and is installed in a cool, well-ventilated area. Also, verify that the inverter is mounted vertically and that the ambient temperature is below the inverter's specified temperature limit.

Sofar solar 5KTLM-G3 Specifications

General IconGeneral
Model5KTLM-G3
Rated Output Power5000 W
Max. DC Input Power7500 W
Max DC Input Voltage1100 V
Number of MPPT2
European Efficiency97.5%
Max. AC Apparent Power5500 VA
Rated Grid Voltage230V
THDi<3%
Protection Degree (IP)IP65
CoolingNatural Convection
AC Output Rated Current21.7A
AC Output Frequency Range50 Hz / 60 Hz
Cooling MethodNatural Convection
Protection LevelIP65
Grid Voltage Range180V-280V
Operating Temperature Range-25°C to +60°C
AC Output Voltage Range180V-280V
Humidity Range0-100% (Non-Condensing)