SOFAR 25~50KTLX-G3 User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd.
- 49 -
Inverter states includes: wait, check, normal and fault
Wait: Inverter is waiting to Check State when reconnect the system. In this state,
grid voltage value is between the max and min limits and so on; If not, Inverter will
go to Fault State or Permanent State.
Check: Inverter is checking isolation resistor, relays, and other safety requirements.
It also does self-test to ensure inverter software and hardware are well functional.
Inverter will go to Fault State or Permanent State if any error or fault occurs.
Normal
Inverter enter to Normal State
it is feeding power to the grid; inverter will
go to Fault State or Permanent state if any error or fault occurs.
Fault: Fault State: Inverter has encountered recoverable error. It should recover if
the errors disappear. If Fault State continues; please check the inverter according
error code.
When the control board and communication board connection fail, the LCD display
interface as shown in the figure below.
6.3. Main Interface
Long press the down button under standard interface to enter into main interface,
Main interface including below information:
Normal
---------Long press DOWN button