SOFAR 1.1K~3KTL User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
LCD display the current state of the inverter,display as shown in the figure below.
Inverter states includes: wait、check、normal、fault and permanent
Wait:Inverter is waiting to Check State at the end of reconnection time. In this
state, grid voltage value is between the max and min limits and so on; If not,
Inverter will go to Fault State or Permanent State.
Check: Inverter is checking isolation resistor, relays, and other safety
requirements. It also does self-test to ensure inverter software and hardware are
functional. Inverter will go to Fault State or Permanent State if any error or fault
occurs.
Normal:Inverter enter to Normal State,it is feeding power to the grid;
inverter will go to Fault State or Permanent state if any error or fault occurs.
Fault:Fault State: Inverter has encountered recoverable error. It should
recover if the errors disappear. If Fault State continues; please check the inverter
according error code.
Permanent:Inverter has encountered unrecoverable error, we need maintainer
debug this kind of error according to error code.