6.4.1. Basic setting:
1. Set Language
Select “1. Language”, press “OK. Press “up” or “down” to select the language and press “OK.
Easier Way: press “Back” & “OKat the same time to change system language.
2. Set Time
Select “2. Time”, press “OK” to enter time setting interface, system time format is 20YY-MM-DD HH:MM:SS
Press Up” or “Down” to change the 1
st
digit, press OKto switch to next digit, after inputting the current time, press
OK.
3. Energy Storage Mode
Select “3. Energy Storage Mode”, press “OK” to enter energy storage mode setting interface.
3.Energy Storage mode
1.Set Auto Mode
2.Set Time-of-use Mode
3.Set Timing Mode
4.Set Passive Mode
1) Set Auto Mode
Select “1. Set Auto Mode”, then press “OK.
In auto mode, HYD-ES inverter will automatically charge & discharge the battery.
1.Basic Setting
Press “OK
Up
“Down”
1.Language
2.Time
3.Energy Storage Mode
4.PV Input Mode
5.EPS Mode
6.Communication Addr.
7.Auto Test
Up
“Down”