6.4.6. Software upgrade
Copy the firmware folder to the root directory of SD card.
Select “6. Software Update”, press OK, “input passwordis shown. Input the password (”0715”), press Upor
“Down” to change the 1
st
digit, press OKto switch to next digit, when “0715” is shown on the screen, press OK.
HYD-ES inverter will start to upgrade the software automatically.
Detailed Firmware Upgrade Procedure:
Step 1 Turn OFF AC circuit breaker (grid & load), then turn OFF DC isolator (battery) and PV switch, then remove
communication waterproof cover. If communication cables (CAN/RS485/NTC/CT) have been connected, loosen their
cable glands before removing cover.
SD card
Step 2 Press the SD card and take it out. Insert the SD card into a micro-SD card reader, then insert micro-SD card
reader into a PC; (NOTE: micro-SD card reader & PC are not provided by SOFARSOLAR).
Step 3 Format the SD card. Copy the “firmware” folder to the SD card.
Step 4 Insert the SD card back to the SD card slot.
Step 5 Turn ON AC circuit breaker (grid), press “Backto enter main menu. Press “Downto select “6. Software
Update”, then pressOk”.
Step 6 “input passwordis shown. Input the password (“0715”), press “Upor “Down” to change the 1
st
digit, press
OKto switch to next digit, when “0715” is shown on the screen, press “Okto start firmware update.
Step 7 After finishing firmware upgrade, turn OFF AC circuit breaker (grid), lock the communication waterproof cover
with four screws, then turn ON AC circuit breaker (grid), turn ON DC isolator (battery), turn on PV switch, HYD-ES
inverter will start to operate automatically.
NOTE: If “DSP communicate fail”, “Update DSP1 Failof “Update DSP2 Failis shown on the screen, which means the