To connect the Ethernet cable:
1. Remove the nut of the COMM1 gland.
CAUTION!
The gland includes a rubber waterproof fitting, which should be used to
ensure proper sealing.
2. Insert the CAT6 Ethernet cable through the gland nut.
3. Remove the rubber fitting.
4. Remove the plastic seal from the rubber fitting.
5. Route the LAN cable through the gland opening in the Synergy Manager.
6.
Insert the CAT6 Cable through the cut into the rubber fitting.
Figure 29: Inserting the Ethernet (CAT6) cable
7. Route the Ethernet (CAT6) cable to the communication board and plug to the LAN
port.
8. Crimp an RJ45 plug onto the Ethernet cable (see Ethernet (CAT6) Cables).
9. Tighten the gland nut with a torque of 5.5 N*m.
Ethernet (CAT6) Cables
CAT6 cables have eight wires (four twisted pairs), as shown in the pin layout of the
Ethernet connector in
Figure 30
. Wire colors may differ from one cable to another. You
can use either wiring standard, as long as both sides of the cable have the same pin-out
Chapter 6: Setting Up Communication with the Monitoring Platform 58
Three Phase Inverter with Synergy Technology P/N: SExxK-xxxxIxxxx SExxK-xxxxIxxxx