Adding, Removing, or Replacing Power Optimizers
1.
Turn OFF the inverter ON/OFF switch, and wait until the LCD indicates that the DC
voltage is safe (<50V), or wait five minutes before continuing to the next step.
WARNING!
If you cannot see the inverter panel, or if a malfunction is indicated on the
LCD panel, wait five minutes for the input capacitors of the inverter to
discharge.
2. Turn OFF the DC Safety Unit (if applicable).
3. Disconnect and connect the necessary power optimizers.
4. Perform pairing and other procedures described in
Commissioning the Installation
on page 36 on all inverters to which power optimizers were added or from which
power optimizers were removed.
5. In the monitoring platform, use the Replace button in the logical
layout tab (in site Admin). Replace the serial number of the removed
power optimizer with the serial number of the newly installed power
optimizer. Refer to https://www.solaredge.com/sites/default/files/se-
monitoring-portal-site-admin.pdf
Appendix F: Replacing and Adding System Components 97
Three Phase System Installation Guide MAN-01-00057-4.1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE7k and is the answer not in the manual?

SolarEdge SE7k Specifications

General IconGeneral
ManufacturerSolarEdge
ModelSE7k
CategoryInverter
Max. DC Power9450 W
Max. AC Power Output7000 W
Rated AC Power7000 W
AC Frequency50/60 Hz
TopologyTransformerless
Warranty12 years
Communication InterfacesRS485, Ethernet
CoolingConvection
Operating Temperature Range-25°C to 60°C