EasyManua.ls Logo

Solartronics FS2000 - PROTECTIONS; 6.1 Pre-warning (buzzer); 6.2 Low voltage protection; 6.3 Over voltage protection

Default Icon
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
E N
N L
6. PROTECTIONS
6.1 Pre-warning (buzzer)
If the input voltage is becoming low, the inverter will emit an acoustic signal as a warning.
6.2 Low voltage protection.
If, after the pre-warning, the input voltage still drops further, the low voltage protection will
eventually take effect. The 230VAC output is shut down and the red indicator ‘fault’ will light.
The buzzer will also continue to sound.
If the input voltage has risen again sufficiently, the inverter will automatically restart.
6.3 Over voltage protection
If the input voltage rises too high, the overvoltage protection will come into effect. The 230VAC
output is shut down and the red ‘fault’ LED lights up. If the input voltage has dropped sufficiently,
the inverter will automatically restart.
Activation De-activation
12Volt models 10,5Vdc +/-0.5 11,5Vdc+/- 0.2
24Volt models 21Vdc+/-0.5 23Vdc+/- 0.2
48Volt models 42Vdc+/-0.5 46Vdc+/- 0.2
Shut down Auto-restart
12Volt models 10,0Vdc+/- 0.5 12,6Vdc+/- 0.2
24Volt models 20Vdc+/- 0.5 25,2Vdc+/- 0.2
48 Volt models 40,0Vdc+/- 0.5 50.4Vdc+/- 0.2