User Manual SPA Snow Pack Analyser
- 33 -
9. Base settings and default values
Menu Parameter description Default value
1. Device identifier 1. Device identifier 0
2. Meas. interval 2. Meas. interval 600
3. Output time 3. Output time After meas
4. RS232 output 4.1 Protocol type MIO extended
4.2 Sync-Out Blank
4.3 Sync-Out hold-back time 10
4.4 Send delay 10
5. RS232 settings 5.1 Baud rate 9600
5.2 Parity None
5.3 Data bits 8
5.4 Stop bits 1
7. SPA parameter 7.1 Snow depth excess 40 mm
7.2 Snow temp default -100 x1/100 C
7.3 Snow temp. meas. None
7.4 Protocol output Excl. input 2 to 5
7.5 Active sensors Sensor 4
8. Sensor_01 8.1 Roll height 2000 mm
8.2 Sensor foot height 80 mm
8.3 Sensor length 4850 mm
8.4 Sensor brace length 150 mm
8.5 Ground length
8.6 Input length corr. 1
8.7 C offset lower frequency 0 exp-13 F
8.8 C offset higher frequency 0 exp-13 F
9. Sensor_02 9.1 Roll height 100 mm
9.2 Sensor foot height 100 mm
9.3 Sensor length 4850 mm
9.4 Sensor brace length 0 mm
9.5 Ground length 0 mm
9.6 Input length corr. 0
9.7 C offset lower frequency 0 exp-13 F
9.8 C offset higher frequency 0 exp-13 F
A. Sensor_03 A.1 Roll height 300 mm
A.2 Sensor foot height 300 mm