CDP-
C75ES/C85ES/C705
Procedure
:
high
tracking
gain
4
high
fandamential
wave
1.
Keep
the
set
horizontal.
Gea
i
ow
Gu
)
If
the
set
is
not
horizontal,
this
adjustment
cannot
be
performed
due
to
the
gravity
against
the
2-axis
device.
2.
Insert
disc
(YEDS-18)
and
press
>
PLAY
button.
3.
Connect
oscilloscope
to
TP
(FEO)
and
TP
(VC)
on
BD
board.
4,
Adjustment
RV102
on
digital
board
so
that
the
waveform
is
as
shown
in
the
figure
below.
(focus
gain
adjustment)
VOLT/DIV:
1V
E
TIME
/DIV:
2mS
VOLT/DIV:
100mV
TIME/DIV
:
2mS
Adjustment
Locations:
(BD
board}
*
Incorrent
Examples
(DC
level
changes
more
than
on
adjust-
ed
waveform)
.
VOLT/DIV:
100mV
low
focus
gain
TIME
/DIV
:
2mS
VOLT/DIV:
100mV
high
focus
gain
TIME
/DIV
:
2mS
5.
Connect
oscilloscope
to
TP
(TEO)
and
TP
(VC)
on
BD
board.
6.
Adjusted
RV101
on
digital
board
so
that
the
waveform
is
as
shown
the
figure
below.
(tracking
gain
adjustment)
*
Incorrect
Examples
(fundamentia
wave
appears)
low
tracking
gain
VOLT/DIV:
1V
TIME/DIV
:
2mS