Command List
FCB-EH6500(GB) A-EEP-100-11(1)
Register Setting
The register settings are enabled when the power is
turned off and then back on again. After turning the
power back on again, verify that the mode settings have
been changed.
Register No. Value
VISCA
Baud Rate
00 00
(Default value)
9600 bps
01 19200 bps
02 38400 bps
03 115200 bps
Monitoring
Mode
72 01
(Default value)
1080i/59.94
02
Reserved
03
NTSC Analog Output
(Stop Digital Output)
04 1080i/50
05
PAL Analog Output
(Stop Digital Output)
06 1080p/29.97
07
Reserved
08 1080p/25
09 720p/59.94
0A
Reserved
0B
Reserved
0C 720p/50
0D
Reserved
0E 720p/29.97
0F
Reserved
10
Reserved
11 720p/25
12
Reserved
13
1080p/59.94
14
1080p/50
Output
Enabling
73 01 Analog Output
enabled
02 Digital Output
enabled
03
(Default value)
Both Analog/Digital
Output enabled
LVDS Mode
74 00
(Default value)
Single output
01 Dual output
Zoom Limit
50 00-FF
(Default value: 00)
Wide Limit
(0: Disabled)
51 00-FF
(Default value: 00)
Tele Limit
(0: Disabled)
D-Zoom Max
52 00-EB
(Default value: EB)
Max. digital
zoom ratio =
256 ÷ (256-Value)
StableZoom 53 00
(Default value: 00)
OFF
01 ON
Temperature Reading Conversion Value
(Reference Value)
Reading Value
pq (hex)
Temperature
Conversion
Value (ºC)
FB −8 to −2
00 −3 to +3
0A 7 to 13
14 17 to 23
1E 27 to 33
28 37 to 43
32 47 to 53
3C 57 to 63