EasyManua.ls Logo

Sony KP-EF41HK2 - 4 Safety Related Adjustment; HV Hold down Adjustment

Sony KP-EF41HK2
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 33 –
KP-EF41HK2/ME2/MN2/SN2, EF48HK2/ME2/MN2/SN2,
KP-EF53HK2/ME2/MN2/SN2 RM-871
SECTION 4
SAFETY RELATED ADJUSTMENT
When replacing the following components marked with
on the schematic diagram, always check hold-down volt-
age and if necessary re-adjust.
4-1. HV HOLD-DOWN ADJUSTMENT
1. Remove CN810. Connect HV meter to HV Block.
2. Connect External Power Supply to CN810 2 pin
(+135V) and 1 pin (GND).
Part Replaced ( )
E Board C515, C516, C554, D504, D507,
L506, Q502, R1, R514, R516,
R517, T502, T504 (FBT)
G Board IC6008
Part Replaced ( )
R1
3. Turn on the set.
4. Slowly up the supply voltage from 0V to 135V.
5. Receive dot picture and set PICTURE/BRIGHT-
NESS to minimum.
6. Slowly up the voltage until hold-down circuit works
(picture disappear).
7. Read the HV meter of peak HV voltage.
Spec: 34.5±0.75KV
8. If Hold-down voltage is less than 33.75KV then sol-
der R1=820K.
9. If hold-down voltage is over than 35.25KV then
take-off R514 and solder R1=9.1K.
+
–
2
CN810
Power
Supply
1
E BOARD
– CONDUCTOR SIDE –
CN810
CN505
CN505
R1
Fig. 4-1
Fig. 4-2
Fig. 4-3
Fig. 4-4
Remove the cap off
from the unused
terminal and connect a
static voltmeter there.
www.freeservicemanuals.info
1/3/16
Published in Heiloo, Holland.