viii
Use the RM-95 to monitor the input voltage
Location Purpose
Page 2,
Address 52.
Read data that corresponds to the input voltage.
This reference voltage will be used next.
Input Camera Shutoff Address Data
The camera shutdown point must be input as data.
1. Set the RM-95 to location Page d, Address 90.
2. Take the data reference number and put it in this address location.
3. Press the Pause button to save the information.
Input Battery Data
As the cameras battery voltage drops, the three shaded LCD battery
symbol inserts drop out to reveal an empty battery. A short time after the
third segment drops out, a flashing battery warning appears on the LCD
screen. These four battery voltage thresholds are inserted as data levels
at page d.
The data reference number from above is in hexadecimal. You must
convert that hexadecimal number to decimal, then add 5. Convert this
new decimal number back to hexadecimal and put that number into Ad-
dress 91.
1. Use the hexadecimal to decimal Conversion Table in the service manual
to change the reference data number at Page d Address 91 to a deci-
mal number. In the example given, hex number AE is looked up in the
chart as decimal 174. The conversion chart is under Data Process in
the table of contents.
2. In a similar process, add decimal number 23 instead of 5, convert it
back to hex and change the data in Page d, Address 92.
3. In a similar process, add decimal number 44 instead of 5, convert it
back to hex and change the data in Page d, Address 93.
4. In a similar process, add decimal number 55 instead of 5, convert it
back to hex and change the data in Page d, Address 94.
Battery Symbol Page d, Address Locations
Name
Page d,
Address
Purpose
D ref 90 Camera shutdown point
D ref + decimal 5 91 Blinking battery warning
D ref + 23 92 LCD battery segment 1
D ref + 44 93 LCD battery segment 2
D ref + 55 94 LCD battery segment 3
D ref (output)
measurement
Page 2,
Address 52
Read DC input voltage as
data.
5. Press the Pause button to save the information after each adjustment
(address change).
Sample Data
The following is data taken from a sample camera.
Sample Data at Page d
Address
Hexadecimal (RM-95)
Data
Decimal e
q
uivalent
(
service
manual chart)
90 85 133 (5.5Vdc)
91 8A 133 + 5 = 138
92 9C 133 + 23 = 156
93 b1 133 + 44 = 177
94 bc 133 + 55 = 188
ref number Decimal
AE 174 179 b3b3