EasyManua.ls Logo

Sony MZ-R50 - MD Walkman MiniDisc Recorder - CD Traverse and RF Level Adjustments

Sony MZ-R50 - MD Walkman MiniDisc Recorder
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 33 –
5-7. Low Reflection CD Traverse Adjustment
Connection :
Adjusting Method :
1. Set the servo mode of the test mode (Mode : 000).
2. Press the key, and set the low reflection CD playback adjust-
ment mode (Mode : 040) using the volume + and – keys.
3. Load any MO disc available on the market.
4. When the key is pressed, the low reflection CD playback EF
balance adjustment mode (Mode : 042) will be set after low re-
flection CD focus search ON (Mode : 041).
5. Press the P key to perform automatic adjustment, and check
that the traverse waveform is symmetrical at the top and bottom.
6. Check that the traverse level at this time is above 0.9Vp-p.
7. Press the p key.
8. Exit the test mode.
5-8. CD Traverse Adjustment
Connection :
Adjusting Method :
1. Set the servo mode of the test mode (Mode : 000).
2. Press the key, and set the CD playback adjustment mode (Mode
: 050) using the volume + and – keys.
3. Press the = and + keys and move the optical pickup to the
center circumference.
4. Load a CD test disc (TDYS-1).
5. When the key is pressed, the CD playback EF balance adjust-
ment mode (Mode : 052) will be set after CD focus search ON
(Mode : 051).
6. Press the P key to perform automatic adjustment, and check
that the traverse waveform is symmetrical at the top and bottom.
7. Check that the traverse level at this time is above 1.0Vp-p.
8. Press the p key.
9. Exit the test mode.
Oscilloscope
MAIN board
TP5980 (TE)
AP5430 (VC)
(Traverse Waveform)
A
B
C
Specification : A = B, C 0.9Vp-p
0V
>
=
Oscilloscop
e
MAIN board
TP5980 (TE)
AP5430 (VC)
(Traverse Waveform)
A
B
C
Specification : A = B, C 1.0 Vp-p
0V
>
=
5-9. CD RF Level Check
Connection :
Adjusting Method :
1. Set the servo mode of the test mode (Mode : 000).
2. Press the key, and set the CD playback adjustment mode (Mode
: 050) using the volume + and -keys.
3. Press the = and + keys and move the optical pickup to the
center circumference.
4. Load a CD test disc (TDYS-1).
5. When the key is pressed, the CD EF balance adjustment mode
(Mode : 052) will be set after CD focus search ON (Mode :
051).
6. When the key is pressed, the ABCD level adjustment mode
(Mode : 053) is set.
7. Press the P key to perform automatic adjustment, and check
that the RF level is 1.1 ±0.3Vp-p.
8. Check that the voltage between AP574 (LDIO) and AP5117
(VCC) and at this time is below 40mV.
9. Press the p key.
10.Exit the test mode.
Digital voltmete
MAIN board
AP5117 (VCC)
AP574 (LDIO)
Oscilloscope
MAIN board
AP5500 (RF)
AP5430 (VC)
1.1 – 0.3 Vp-p
(RF waveform)

Related product manuals