SECTION
4
MECHANICAL
ADJUSTMENTS
Precautions
1.
Input
a
DC
3.0V
power
supply
to
the
DC
IN
3V
jack.
To
clean
the
drum,
moisten
a
chamois
leather
(2-034-697-00)
or
cloth
(knit)
that
has
been
folded
into
fours
with
alcohol
slightly,
press
it
lightly
against
the
drum
and
rotate
the
drum
in
the
counterclockwise
direction
(2
to
3
times).
Torque
Check
TW-7131
3.5
to
5.5g*cm
(8-909-708-71)
(S
side)
REVIEW
(44
=
D>
+
44)
back
Tension
TW-7131
(8-909-708-71)
0.5
to
1.5g*¢cm
(T
side)
Tape
Path
Adjustment
Be
sure
to
perform
this
adjustment
when.the
drum,
S
side
roller
guide
section
parts
and
T
side
roller
guide
section
parts
are
replaced.
Procedure:
1.
Remove
the.
cassette
lid
assembly
and
case
assembly.
2.
Connect
CH1
of
an
oscilloscope
to
TP80
(RF)
and
TP79
(RF
GND)
of
the
main
board,
then
CH2
(trigger)
to
TP78
(SWP).
Main
board
(side
A)
TP79
(RF
GND)
TP8O
(RF)
TP78
(SWP)
3.
Load
the
test
tape
TY-7231
(8-119-874-00)
and
press
PLAY
(P>).
4,
Check
that
the
waveform
of
the
oscilloscope
(RF
signal)
becomes
®,®.©.0,
©,
®,
or
©
shown
in
Fig.
1
(There
must
be
two
peaks
or
less
and
the
marginal
area
must
appear
as
well.).
If
the
specification
is
not
satisfied,
perform
adjustments
from
step
5.
If
the
specification
is
satisfied,
perform
adjustments
from
step
7.
Marginal
area
Marginal
area
0
peak
0.5
peak
1
peak
1
peak
1.5
peaks
2
peaks
2
peaks
©
There
must
be
two
peaks
or
less
and
the
marginal
area
must
appear
as
well,
«
Approximate
upper
waveform
value:
0.4
to
0.6
mV
when
the
waveform
is
most
spread.
Fig.
1.