190
The enable/disable setting is applied to all Virtual Shot 
Box, Virtual Menu, and Virtual Panel instances connected 
to the control panel.
1
Open the Misc >Enable >Port Enable menu (3211).
2
Press [Web UI Enable] to enable/disable the function.
The setting switches between enabled (button is lit) 
and disabled (button is not lit) each time [Web UI 
Enable] is pressed.
Setting the Safe Title Area
You can enable/disable the safe title area for each output.
1
Open the Misc >Safe Title menu (3221).
2
Select the target signal.
• It is not possible to change the setting for outputs for 
which the safe title area is disabled in the Setup 
menu.
For details, see “Setting the Safe Title Area” 
(page 459).
• If an input with through mode enabled is selected for 
output on an AUX bus or edit preview bus with 
through mode enabled, the safe title area becomes 
disabled.
3
Press [Safe Title] to enable/disable the function.
The safe title area switches to enabled (button is lit) or 
disabled (button is not lit) each time the button is 
pressed.
Displaying a List of Transition Rates 
and Changing the Settings
In the Misc >Transition >Key/ME/FTB menu (3231), you 
can display a list of the M/E (or PGM/PST) transition rates 
and independent key transition rates for each bank, and 
change the settings.
These settings are linked to the corresponding transition 
rate setting operations on each bank.
You can also display and set the fade-to-black transition 
rate.
Misc >Transition >Key/ME/FTB menu
The display of the independent key transition rate in the 
Misc >Transition >Key/ME/FTB menu (3231) depends on 
the selection in the <Key Transition> group of the 
Engineering Setup >Switcher >Transition menu (7334) on 
each bank.
When [Same] (same setting for key insertion and key 
removal) is selected in the <Key Transition> group: 
Only “Key” appears.
When [Independ] (independent settings for key 
insertion and key removal) is selected in the <Key 
Transition> group: “Key (On)” and “Key (Off)” 
appear.
For details, see “Selecting independent key transition 
mode” (page 469).
Setting the transition rate
To set the M/E transition rate
This section describes setting on the M/E-1 bank as an 
example.
1
In the status area of the Misc >Transition >Key/ME/
FTB menu (3231), select [M/E-1].
2
In the <Transition Rate> group, press [Transition].
3
Set the transition rate.
When a clip transition is selected as the transition type, 
it is not possible to change the transition rate in the 
Key/ME/FTB menu.
To set the independent key transition rate
This section describes setting key 1 to key 4 on the M/E-1 
bank as an example.
1
In the status area of the Misc >Transition >Key/ME/
FTB menu (3231), select [M/E-1].
2
In the <Transition Rate> group, press [Key K1-K4].
When [Independ] is selected in the <Key Transition> 
group of the Engineering Setup >Switcher >Transition 
menu (7334), press [Key (On) K1-K4] or [Key (Off) 
K1-K4].
3
Set the transition rate.
Note
Notes
No. Parameter Adjustment
1 Transition 
Rate
Transition rate
Note
No. Parameter Adjustment
1Key1 Trans 
Rate
Key 1 transition rate