433
Setting Device Control Block Button 
and Trackball Operation
In the Engineering Setup >Panel >Operation menu (7326), 
press [Sensitivity] to open the Sensitivity menu (7326.5).
Configure each function, as required.
Setting the trackball and Z-ring sensitivity in 
normal mode
In the <Trackball Normal Mode> group, select one of the 
following.
×1: Standard (default travel speed)
×2: Move at 2× speed.
×4: Move at 4× speed.
This setting is disabled in the following operation modes.
• Keyframe operation mode
• VTR/disk recorder/frame memory operation mode
Setting the trackball and Z-ring sensitivity in fine 
mode
In the <Trackball Fine Mode> group, select one of the 
following.
1/2: Move at 1/2 speed
1/4: Move at 1/4 speed
1/8: Move at 1/8 speed
This setting is disabled in the following operation modes.
• Keyframe operation mode
• VTR/disk recorder/frame memory operation mode
Setting the sensitivity when recalling a menu 
using button double-press
In the <Double Click> group, select one of the following.
Fast: High speed
Normal: Normal
Slow: Low speed
Setting the Macro Operation Mode
In the Engineering Setup >Panel >Operation menu (7326), 
press [Macro] to open the Macro menu (7326.6).
Configure each function, as required.
Setting the macro execution mode
In the <Macro Execution Mode> group, select one of the 
following.
Normal: Set normal execution mode.
Step: Set step execution mode.
Enabling simultaneous multiple macro execution
Press [Macro Multi Mode], turning it on.
Macro multi mode is enabled.
Setting button actions when configuring macro 
attachments
In the <Attachment Setting Mode> group, select one of the 
following.
With Btn Function: Simultaneously execute button 
function.
W/o Btn Function: Do not execute button function.
Setting the action during macro execution or 
when a macro is paused if the same macro is 
recalled
In the <Macro 2nd Recall Mode> group, select one of the 
following.
Continue: If the macro is recalled by operation of the 
same button that executed a macro attachment, resume 
execution of a paused macro or continue execution of 
an executing macro as-is. If the macro is recalled by 
any method other than a macro attachment, execution 
starts from the first event.
Cancel: Stop the executing macro or paused macro.
Setting the action during macro execution or 
when a macro is paused if another macro is 
recalled
In the <Macro Recall Override> group, select one of the 
following.
Disable: Ignore the other macro recall.
Enable: Stop the executing macro or paused macro, and 
execute the other macro.
When multi mode is enabled and macros are recalled using 
buttons for which simultaneous execution is supported, the 
settings in the <Macro Recall Override> group are 
disabled. Other macros are also executed simultaneously.
Setting the enable/disable macro attachment 
configuration mode
In the <Macro Attach Enable Setting Mode> group, select 
one of the following.
Manual: Enable/disable using the [MACRO ATTACH 
ENABLE] button on the cross-point pad of the cross-
point control block or the button assigned with the 
“Macro Attachment Enbl” utility command.
Enable: Always enable macro attachments.
Disable: Always disable macro attachments.
Setting cross-point buttons with a macro 
attachment to be lit continuously
Press [Attchd Btn Indication], turning it on.
When macro attachments for the cross-point control block 
are enabled, cross-point buttons with a macro attachment 
are always lit green.
No. Parameter Adjustment
1 Ignore 
Fields
Time in which double-press is 
prevented (1 to 15 fields)
Note
Note
Note