INSTRUCTION AND SERVICE PARTS MANUAL - FREEZER CS 800, s/n F0176-00 - ALFRED & CO
L10
9.3.5. STOPPING AND RESTARTING MACHINE DURING PRODUCTION
Stopping
• Stop refrigeration ( pos.16).
• Stop pump ( pos. 1) and booster pump if used.
• Stop dasher if shut-down is to be longer than 10 minutes ( pos. 2 ).
Restarting
• Start dasher ( pos. 4 ).
• Start refrigeration ( pos. 14 ).
• Start pumps ( pos. 3).
• Also start booster pump at the same time.
9.3.6. STOPPING MACHINE AT THE END OF RUN
When mix tank is nearly empty, add water and follow the procedure given
below:
• Stop refrigeration ( pos. 16 ).
• After a short period of time finished product will soften and become
less viscous.
• Open hand-operated full-flow covers of mix and ice cream pumps.
• Turn the pneumatic air-operated full-flow covers of mix and ice cream
pumps switch into “C.I.P” position (pos. 15)
• Stop booster pump when mix tank is empty or when water becomes
clear.
• Stop dasher ( pos. 2 ).
• Turn off condenser cooling water.
• Machine is now ready for in-place cleaning.