10.3.4. RINSE
The purpose of this step is to rince the system clear of the chemical
solution and removed soil.
Use water at 50 -60°C:
At the start of this step, route the return into the cleaning solution tank to
recover the solution remaining in the system. After an appropriate time,
divert to drain.
Continue to rinse until returning water is clear of chemical and removed
soil.
10.3.5. ACID WASH
WARNING !
The inner cylinder of freezer is chrome plated: do not use acid wash step
as chrome has no resistance to acid attack!
10.3.6 SANITIZING
Sanitizing is use to kill bacteria on product contact surfaces of the unit.
When using chemical solutions, sanitizing should be performed no
earlier than 15 minutes prior to processing product. The chemicals
commonly used for sanitizing (chlorine or iodine containing compounds)
are extremely corrosive.
Solution strength and exposure time must be closely regulated.
Hot water may be use for sanitizing to avoid the corrosive effect of
chemical solutions.