INSTRUCTION AND SERVICE PARTS MANUAL - FREEZER CS 800, s/n F0176-00 - ALFRED & CO
N5
Seals improperly installed.
EXCESSIVE BEARING WEAR
Oil contamination.
Operating at excessive pressure and at excessive speeds.
Improper bearing adjustment
OIL CONTAMINATION
Prolonged product leakage.
Failure to change oil.
Breather positioned wrong.
Oil seals improperly installed.
Failure to clean gear case front regularly.
SHORT LIFE FOR SHAFT SEAL
Running pump dry.
Nicks or burrs in seal bearings or in seal cavity.
Improper seal installation.
Loose bearings.
EXCESSIVE ROTOR WEAR
Running pump dry.
Pumping abrasive product.
Circulating cleaning solution with rotors in.
Nicks in body and cover.
Excessive speeds and pressures.
Extreme and sudden product temperature changes.
ROTOR DAMAGE
Running pump dry.
Hard substances passing through pump.
Loose bearings.
Nicks and burrs in cover and body.
OIL LEAK
Breather plugged.
Oil seal excessively worn.