8,
ELECTRIC PANEL
BSS-134
CHAP.- 8
T89 DELAY CLOSED CLAM = it is a closing delay of the horizontal pliers after a withdrawal.
T90 TIME FOLD = it is the time elapsing from when the blind bags are closed to when the pliers start
closing.
T91 TIME MANUAL JUNCTIO = it is the manual sealing time when a net/fi lm or net coil is replaced.
T92 DELAY START NET = it is the delay for the net/fi lm net withdrawal to start after the pliers open.
T93 TIME BELT CONVEYOR = it is the moving time of the fi nished package outlet belt.
T94 HOPPER UP = it is the time need for the hopper vibrator to start moving upwards (when the
machine is equipped with a hopper).
T95 HOPPER DOWN = it is the time need for the hopper vibrator to start moving downwards (when
the machine is equipped with a hopper).
T96 DELAY START TRANSFER = it is the delay time after which the label is requested when the
withdrawal cycle is over.
T97 DELAY CLAMP OPEN = it is the time elapsing from the end of a machine cycle to the beginning
of the next one.
T98 DELAY FRUIT FALL = it is the delay time for fruit fall on the pliers from when the unloading
hopper is closed (optional).
T99 DELAY FRUIT READING WITH STEP HOPPER = it is the delay time of the photocell reading
the fruit falling from the hopper.
500 NR. CYCLE HOPPER = it is the number of cycles of hopper vibrator (if the machine is equipped
with a hopper).
501 NR. CYCLE END NET = it is the number of cycles carried out by the machine after detecting
the net end.
502 = free option.
503 = free option.
By pressing from page 32, page 41 will appear