16
Specifications cont.
400.0µA
4000µA
40.00mA
400.0mA
10.00A
All AC current ranges are specified from 5% to 100% of range.
Input Protection: µA/mA ranges: 500mA/600V Fuse
10A range: 10A/600V Fuse
0.1µA
10µA
0.1mA
10mA
±(2.0% +5 digits)
±(2.5% +5 digits)
±(3.0% +7 digits)
AC Current
50/60Hz
Function Range Resolution Accuracy
± (% of reading + digits)
400.0µA
4000µ
40.00mA
400.0mA
10.00A
Input Protection: µA/mA ranges: 500mA/600V Fuse
10A range: 10A/600V Fuse
0.1µA
1µA
10µA
0.1mA
10mA
±(1.0% +3 digits)
±(1.5% +3 digits)
±(2.5% +5 digits)
DC Current
Function Range Resolution Accuracy
± (% of reading + digits)
15
Specifications cont.
4.000V
40.00V
400.0V
600V
All AC voltage ranges are specified from 5% to 100% of range.
Input Protection: 600V RMS or 600V DC
Accuracy is given at 65°F to 83°F (18°C to 28°C), less than 70% relative humidity
1mV
10mV
0.1V
1V
±(1.0% +5 digits)
±(1.2% +5 digits)
AC Voltage
50/60Hz
Function Range Resolution Accuracy
± (% of reading + digits)
400.0mV
4.000V
40.00V
400.0V
600V
Input Protection: 600V RMS or 600V DC
0.1mV
1mV
10mV
0.1V
1V
±(1.0% +8 digits)
±(1.0% +3 digits)
±(1.2% +3 digits)
DC Voltage
Function Range Resolution Accuracy
± (% of reading + digits)
9.999Hz
99.99Hz
999.9Hz
9.999kHz
Input Protection: 600V RMS or 600V DC
0.001Hz
0.01Hz
0.1Hz
1Hz
±(1.0% +5 digits)
Frequency
Sensitivity:
100V < 50Hz
50V 50 to 400Hz
5V > 400Hz to 4000Hz
Function Range Resolution Accuracy
± (% of reading + digits)
20.0%
to
80.0%
Input Protection: 600V RMS or 600V DC
0.1%
±(1.2% +5 digits)
% Duty Cycle
Pulse width:
>100us, <100ms;
Frequency width:
5Hz – 150kHz
Sensitivity: >1V RMS
Function Range Resolution Accuracy
± (% of reading + digits)