Light flashes
2 times
Light over heating
Light flashing Blue
continuously
System is in
“Reset” mode
Refer to multi-colour
operating instructions
If these issues cannot be resolved with the above recommended actions,
please contact your local Spa Electrics reseller or Spa Electrics directly.
Phone: +61 (0)3 9793 2299 (business hours)
Email: info@spaelectrics.com.au (SALES enquiries)
Email: tech@spaelectrics.com.au (TECHNICAL support enquiries)
Web: www.spaelectrics.com.au
Check light is fully submerged.
Check vents are not obstructed
Light not operating (1) Faulty connection
to transformer
Ensure cable correctly connected
to transformer terminals
Light not operating (3) Damaged cable
Light not operating (2) Mains power not
connected
Check transformer is plugged in
to GPO and switched on
Light not operating (4) Transformer not
working
Check fuses & test transformer
using multimeter under load
(ie.15W 12V)
Light not operating (5) Damage caused by
high voltage and/or
incorrect power supply.
Return product to your local Spa
Electrics reseller or Spa Electrics
for repair
Light colours not
synchronised
Power interruptions or
lights have been used
individually
Reset lights - refer to multi-
colour operating instructions
Disconnect plug top and test
voltage under load using
multi-meter (ie. 20w 12v)
Light flashes green Over-voltage detected
Ensure transformer output
voltage is between 12V ~ 13V.
Replace transformer if necessary.
21
ISSUE REASON ACTION
TROUBLESHOOTING