IMPORTANT
Make only small adjustments to viscosity setting; allow at least 10 to 15 minutes between adjustments to evaluate
product firmness. Viscosity settings should not need continuous adjustment and should be set between 1.75 and
3.25, with 2.50 a good starting place.
FROZEN PRODUCT OPERATION
ADJUST PRODUCT CONSISTENCY
Press RESET to stop machine functions. Press and hold
RESET until display shows settings (viscosity is the first
setting shown). If you scroll past the viscosity setting,
hit RESET until it comes back around.
Press STANDBY to increase viscosity (more firm).
Press P to decrease viscosity (less firm).
Press and hold ARROW for 3
seconds to save changes.
Press RESET to return to normal
machine operation.
Press FREEZE to return to freezing operation.
1
2
3
4
5
6
Spaceman USA Soft Serve Pump Training