Extreme caution must be exercised while operating under either the safety override or power
override mode. Safety override should be used only when the operator cannot correct the problem
causing carriage shut down. Power override should be used only during times of a power outage.
Spacesaver area contractor service personnel should be called at once to correct any problem
necessitating the use of the safety override key. The safety override key should be used only by
supervisors or service personnel.
While operating a carriage using the safety override key it will travel at a reduced rate of
speed, a warning beeper will sound as the carriage moves and the metal key must be toggled and
held during carriage movement.
The safety override key is not required to move a carriage away from a safety fault.
USING THE SAFETY OVERRIDE FUNCTION:
ATTN: AREA SUPERVISOR ONLY
OPERATIONS INSTRUCTIONS
for Power Assist and PowerPro
®
Safety and Power Override Functions
TouchPad Control Only
1. When a safety fault occurs the L.E.D. light on the control
will begin to blink. A push of the control will cause the
L.E.D. light to stop blinking and glow steady red.
2. Insert the safety override key into the opening just above
the key slot. The L.E.D. light will begin to flutter.
3. Insert the metal key into the key slot. Toggle the key
clockwise for right movement or counter clockwise for left
movement as required. 40 seconds are allowed to
accomplish the carriage move. If the move is not
completed within this time frame, remove and reinsert the
safety override key to purchase an additional 40 seconds.
Note: The metal key
may be used to move
carriages at any time,
not just during times of a
safety fault. This key
should be kept by the
area supervisor for
security reasons.