OP-0206
Attention Service Person Only
Power Assist & PowerPro
®
TouchPad
Control
Installation, Setup and Service
Subject: Function and use of 2 pin jumper locations at JP1-8.
Location JP1 – Beeper options:
No jumper: Beeper will sound when keys are pushed.
Jumper: Beeper will not sound when keys are pushed.
Location JP2 – Operating mode:
No jumper: Normal control mode. The control will initiate the appropriate move when the
code is entered.
Jumper: Locking mode. The touch pad allows the user to lock a module or a carriage.
Entering the appropriate code enables the locking. Re-entering the code disables
the locking.
Location JP3 – Not used
Location JP4 – Default reset upon power up*.
No jumper: The control will operate when the customer programmed code is used.
Jumper: The control will default to 1-2-3-4 upon power up.
Service person action required:
Symptom: The customer is unable to determine which code is active.
Cause: Someone has changed the code and has not informed the group. Could
be vandalism or an oversight.
Solution: Place a jumper at location JP4. Remove the TouchPad connector at the
back of the board and reconnect. The system will default to 1-2-3-4. Remove the jumper at
location JP4. The customer is now free to enter a new code.
Location JP5 – Jumper to enable 5-digit code.
Location JP6 – Jumper to enable 6-digit code.
Location JP5 & 6 – Jumper to enable 7-digit code.
Location JP7 & 8 – Reserved for future
Subject: To establish lock left or lock right action of the system.
As part of the control installation, the 2 conductor wire in the 4 pin header must be properly
placed. Place this header at J3 or J8 depending if close left or close right is desired. The board is silk
screened with the right or left designation to aid in this procedure. See the drawing on the back of this page
for wiring detail.
Note: The production planning department MUST be given prior knowledge of the lock left or lock right
preference. The face panel on the systems left or right will be routed to accept the “Close button”.