Figure 5.1: Spectra Zone Programming
5.5 ZONE DEFINITIONS
As demonstrated in Figure 5.1, sections [001] to [015] represent zones 1 through 15 respectively, where the first digit in each of
these sections represents the zone's definition. Also, refer to Zone Speed on page 18. To disable a zone, clear the contents of the
section corresponding to the desired zone by pressing the [
FORCE] key 3 times and pressing [ENTER]. There are 9 available Zone
Definitions, which are described as follows.
5.5.1 ENTRY DELAY 1
Sections [001] to [015]: Zones 1 to 15, First Digit = 1
When the system is armed and a zone defined with Entry Delay 1 opens, the control panel will generate an alarm after
the programmed Entry Delay 1 Timer elapses. This is to provide users with enough time to enter the protected area
and disarm the system. To program the Entry Delay 1 Timer, key in the desired 3-digit delay value (000 to 255
seconds, Default = 45 seconds) into section [069]. Entry Delay zones are commonly used at the entry/exit points of the
protected area (i.e. front/back door, garage, etc.). Using different Entry Delays (see Entry Delay 2 below) is useful
when, for example, one entry point requires a longer delay than the other entry point or in a partitioned system where
each partition may require a different Entry Delay.
5.5.2 ENTRY DELAY 2
Sections [001] to [015]: Zones 1 to 15, First Digit = 2
Entry Delay 2 zones are identical to the Entry Delay 1 zones (see section 5.5.1), except it uses a separate Entry Delay
Timer. To program the Entry Delay 2 Timer, key in the desired 3-digit delay value (000 to 255 seconds, Default = 45
seconds) into section [070].
This timer is also used as the Stay Delay timer (see Stay Arming with Delay on page 24).
Zone Definitions
1 - Entry Delay 1
2 - Entry Delay 2
3 - Follow
4 - Instant
5 - 24Hr. Burglary
6 - 24Hr. Buzzer
Additional definitions for
on-board terminals:
7 - Keyswitch
8 - 24Hr. Fire
9 - 24Hr. Delayed Fire
Press the
[
ENTER] key
Enter the
[
INSTALLER CODE]
Key in 3-digit
[
SECTION]
Zone Definition
First Digit
Zone Partition
Assignment
Second Digit
Zone Options
Feature Select
Press [ENTER]
[001] = Zone 1 [009] = Zone 9
[002] = Zone 2 [010] = Zone 10
[003] = Zone 3 [011] = Zone 11
[004] = Zone 4 [012] = Zone 12
[005] = Zone 5 [013] = Zone 13
[006] = Zone 6 [014] = Zone 14
[007] = Zone 7 [015] = Zone 15
[008] = Zone 8
Zone Partition Assignment
1 - Zone Assigned to Partition 1
2 - Zone Assigned to Partition 2
3 - Zone Assigned to both Partitions
Zone Options
[1] Auto Zone Shutdown Enabled
[2] Bypass Enabled
[3] Stay Zone
[4] [5] Zone Alarm Type
OFF OFF Audible Alarm (steady)
OFF ON Audible Alarm (pulsed)
ON OFF Silent Alarm
ON ON Generates only a report
[6] Intellizone
[7] Delay alarm transmission
[8] Force Zone
Keyswitch Options
[1] OFF= Maintained
ON = Momentary
[2] OFF = Regular Arm
ON = Stay Arm
Keypads beep twice
Select
one
Select
one