Spectra 1759EX - 1 - Programming Guide
1759EX
S
YSTEM PROGRAMMING GUIDE
Software Version 1.0
DEFAULT INSTALLER CODE
0000 / 000000 (see section [281] on page 18)
DEFAULT SYSTEM MASTER CODE
1234 / 123456 (see section [301] on page 18)
HOW DO I ENTER PROGRAMMING MODE?
ST EP 1: Pr ess
[
ENTE R
]
ST EP 2: En ter yo u r
[
IN ST A LL E R
CODE
]
ST EP 3: En ter 3 -digit
[
SE CTION
]
you wish to program
ST EP 4: En ter r equi red [DATA]
DECIMAL AND HEXADECIMAL PROGRAMMIN G TABLE
TR OUB LE DI SPL AY
Press the [TBL] or [TRBL] key to view the Trouble Display. Plea se no te that the keyp ad ca n be pr ogrammed to emit a BEEP
every 5 seconds whenever a new trouble condition has occurred. Press the [TBL] or [TRBL] key to stop the beeping.
[1]
- No Battery or Low Battery
[8]
- Ti mer Loss**
[2]
- Wireless Transmitter Low Battery
[9]
- Tamper or Zone Wiring Failure*
[3]
- Power Failure
[10]
- Teleph one Line Monitoring Failure
[4]
- Bell Output Disconnected [11]/[STAY] - Fire Loop Trouble*
[5]
- Maximum Bell Current [12]/[BYP] - Module Loss
[6]
- Maximum Auxili ary C urrent [13]/[MEM] - Wireless Transmitter Supervision Loss*
[7]
- Communicator Report Failure [16]/[FORCE] and [TBL]/[TRBL] flashes - Keypad Fault
* press the illuminated key ([9], [STAY ] or [ME M]) to view which zones are causing the trouble. Enter the Installer Code to clear
Tamper troubles.
** press [8] to re-program the time.
Value or Action
What Do I
Press?
What Do I See?
10-Zone LED 16-Zone LED LCD
Values 1 to 9 [1] to [9]
[1]
to
[9] [1]
to
[9 ] [1]
to
[9 ]
A (hexa only) [0] [0 (10)][10] 0
B (hexa only)
[ST AY][STAY]
[11] B
C (hexa only)
[BYP][BYP]
[12] C
D (hexa only)
[MEM][MEM]
[13] D
E (hexa only)
[TBL] / [TRBL][TBL]
[14] E
F (hexa only)
[PG ] / [FNC1][PG]
[15] F
Exit Without Saving
[CLEAR]
[ENTER] flashes [ARM1] & [STAY 1] flash āSECTION [ ]ā
Era se Current Di git
[FORC E]
Displays next digit or next section
Save Data (hexa only)
[ENTER]
Advances to the next section