Spectr a 175 9EX - 21 - Programming Guide
PRINTER MODULE V2.0
Due to the APR3- PRT 1’s Auto- recognition featur e, it can be u sed w ith either the Spectr a (V2 .0 or h igher), Digipl ex or
DigiplexNE control panel. When connected to the bus, the APR3-PRT 1 automatically detects which control panel it is
connected to and adjusts its internal communication parameters to function accordingly. Only one APR3-PRT1 can be
connected to each Spectra control panel.
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules with the
APR3- prefix are compatible with Spectra (versions 2.0 and higher), Digiplex and DigiplexNE.
Bold = Default Setting
SECTION [550]: GENERAL OPTIONS
Opt ion
OFF ON
[1] Assi gn ed to Partition 1 N Disabled N Enabled
[2] Assi gn ed to Partition 2 N Disabled N Enabled
[3] PGM normal state N Normally Open (N.O.) N Normally Closed (N.C.)
[4] Print Arming and disarming events N Disabled N Automatically
[5] Print Alarm and Alarm Restore events N Disabled N Automatically
[6] Print Tamper and Tamper Restore events N Disabled N Automatically
[7] Print Trouble and Trouble Restore events N Disabled N Automatically
[8] Print Special events N Disabled N Automatically
SECTION [551]: AUTOMATIC ZONE STATUS PRINTING
Opt ion
OFF ON
[1] Print status of Zone 1 N Disabled N Automatically
[2] Print status of Zone 2 N Disabled N Automatically
[3] Print status of Zone 3 N Disabled N Automatically
[4] Print status of Zone 4 N Disabled N Automatically
[5] Print status of Zone 5 N Disabled N Automatically
[6] Print status of Zone 6 N Disabled N Automatically
[7] Print status of Zone 7 N Disabled N Automatically
[8] Print status of Zone 8 N Disabled N Automatically
SECTION [552]: AUTOMATIC ZONE STATUS PRINTING
Opt ion
OFF ON
[1] Print status of Zone 9 N Disabled N Automatically
[2] Print status of Zone 10 N Disabled N Automatically
[3] Print status of Zone 11 N Disabled N Automatically
[4] Print status of Zone 12 N Disabled N Automatically
[5] Print status of Zone 13 N Disabled N Automatically
[6] Print status of Zone 14 N Disabled N Automatically
[7] Print status of Zone 15 N Disabled N Automatically
[8] N/A N N/A N N/A