Spectr a 175 9EX - 27 - Programming Guide
ZONE EXPANSION BUS MODULES
Only one SPC /APR3- ZX4 or o ne SPC/APR3-ZX8 can be co nnected to each Spe ctra control p anel . The followin g se cti ons
are for SPC-ZX4 version 1.0, APR3-ZX4 version 1.0, SPC-ZX8 version 1.0 and APR3-ZX8 version 2.0.
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules with the
APR3- prefix are compatible with Spectra (versions 2.0 and higher), Digiplex and DigiplexNE.
Bold = Default Setting
PGM PROGRAMMING (SPC-ZX8 an d APR3-ZX8 Only)
The PGM will only activate or deactivate 100mS after the selected event occurs. The PGM Deactivation event can be used
as another activation event if the PGM Timer (section [655]) is programmed with a value other than 000. The system will
ignore the PGM if it has been programmed to follow the Global PGM (option [3] in section [650]). Only PGM events from the
table below can be used.
Section # Decimal Value (000-255) Description Default Value
[655] ___/___/___ seconds (000 = follow deactivation event) PG M1 TIMER 5 sec.
Section # Event Group # Sub-Group # Partition #
[656] PGM1 Acti vation Event ___/___ ___/___ __ _/___
[657] PGM1 Deactivation Event ___/___ ___/___ __ _/___
SECTION [650]: Options
Op ti on
OFF ON
[1]
EOL (end-of-line) resistors for hardwire modules N No EOL N Use EOL Resistors
[2]
Zone Expansion Module tamper recognition N Disabled N Z1 becomes tamper input
[3]
PGM 1 on SPC/APR 3-Z X8 fo llows Global PGM
pr ogrammed in sections [124] & [1 25]
N Disabled N Enabled
[4]-[8]
Future Use N N/A N N/A
SECTION [651]: ZONE ASSIGNMENT
Option SeeZone Recognition Table on page 6. OFF ON
[1] Input Z1 =Expansion Input 1 N Disabled N En ab le d
[2] Input Z2 =Expansion Input 2 N Disabled N En ab le d
[3] Input Z3 =Expansion Input 3 N Disabled N En ab le d
[4] Input Z4 =Expansion Input 4 N Disabled N En ab le d
[5] Input Z5 (SPC/APR3- ZX8 on ly) =Expansi on Input 5 N Disabled N En ab le d
[6] Input Z6 (SPC/APR3- ZX8 only) =Expansion Input 6 N Disabled N En ab le d
[7] Input Z7 (SPC/APR3- ZX8 only) =Expansi on Input 7 N Disabled N En ab le d
[8] Input Z8 (SPC/APR3- ZX8 only) =Expa nsi on Input 8 N Disabled N En ab led
Event Group # Sub-Group # Partition #
For SPC-ZX8:
60 = Hardwire Zone Opened
61 = Hardwire Zone Closed
62 = Hardwire Tamper Opened
63 = Hardwire Tamper Closed
For APR3-ZX8:
60 = Hardwire Zone/Hardwire Tamper Opened
61 = Hardwire Zone/Hardwire Tamper Closed
01 = Expansion Input 1 - Section [651] - [1]
02 = Expansion Input 2 - Section [651] - [2]
03 = Expansion Input 3 - Section [651] - [3]
04 = Expansion Input 4 - Section [651] - [4]
05 = Expansion Input 5 - Section [651] - [5]
06 = Expansion Input 6 - Section [651] - [6]
07 = Expansion Input 7 - Section [651] - [7]
08 = Expansion Input 8 - Section [651] - [8]
99 = Any zone exp ansion bu s module in put
Not u sed; enter 00