Spectra 1759EX - 12 - Programming Guide
SYSTEM OPTIONS
Bold = Default Setting
* Reassign Zone s to Expansion Inputs changes the zone numbering to increase the number of expansion inputs that can be
displayed on 10-Zone LED Keypads. Refer to Spectra 1759EX Referen ce & Installation Manual for details.
SECTION [126]: General Options
Op ti on
OFF ON
[1]
Confiden tial M ode N Disabled N Enabled
[2]
To exit Confidential Mode N Enter Access Code N Press a Key
[3]
Confiden tial M ode timer N 2 minutes N 5 seconds
[4]
PGM 1 no rmal state N Normally Open (N.O.) N Normally Closed (N.C.)
[5]
PGM 2 no rmal state N Normally Open (N.O.) N Normally Closed (N.C.)
[6]
Glob al PGM norm al state N Normally Open (N.O.) N Normally Closed (N.C.)
[7]
Reassign Keypad Zone 2 N Disabled N Enabled
[8]
Reassign zone s to expansion inputs* N Disabled N Enabled
SECTION [127]: General Options
Op ti on
OFF ON
[1]
Partitioning N Disabled N Enabled
[2]
Access code length N 6-di gits N 4-digits
[3]
Keypad audible trouble warning N Disabled N Enabled
[4]
Lock System Master Code N Disabled N Enabled
[5]
Battery char ge current N 350mA N 700mA
[6]
User Code 048 is a Duress Code N Disabled N Enabled
[7]
Al arm rel ay follows N Bell Output N Global PGM
[8]
Future use N N/A N N/A
SECTION [128]: General Options
Op ti on
OFF ON
[1]
Panic 1: keys [1] & [3] N Disabled N Enabled
[2]
Panic 2: keys [4] & [6] N Disabled N Enabled
[3]
Panic 3: keys [7] & [9] N Disabled N Enabled
[4]
Panic 1: silent or audible N Silent N Audible
[5]
Panic 2: silent or audible N Silent N Audible
[6]
Panic 3: silent or fir e N Silent N Fire
[7]
Keypad 1 tamper supervision N Disabled N Enabled
[8]
Keypad 2 tamper supervision N Disabled N Enabled
SECTION [129]: General Options
Op ti on
OFF ON
[1]
PGM2 output activation option N Steady N Pulse (flash)
[2]
PGM2 pulse once every 30 sec. if system armed N Disabled N Enabled
[3]
PGM2 pulse on Arm, twice on Disarm N Disabled N Enabled
[4]
ZX4 & ZX8 zone expansion module supervision N Disabled N Enabled
[5]
Future use N N/A N N/A
[6]
Wireless module low battery supervision N Disabled N Enabled
[7]
4-PGM Output Module supervision (APR3-PGM4) N Disabled N Enabled
[8]
Printer Module supervision (APR3-PRT1) N Disabled N Enabled