Spectra 1759EX - 22 - Programming Guide
Bold = Default Setting
PGM PROGRAMMING
The PGM Deactivation event can be used as another activation event if the PGM Timer (section [554]) is programmed with a
value other than 000. The APR3-PRT1 module uses the same PGM events as the Spectra control panel, please refer to
“Programmable Outputs” on page 9
Section # Decimal Value (000-255) Description Default Value
[554] ___/___/___ seconds (000 = follow deactivation event) PG M1 TIMER 5 sec.
Section # Event Group # Sub-Group # Partition #
[555] PGM1 Acti vation Event ___/___ ___/___ ___/___
[556] PGM1 Deactivation Event ___/___ ___/___ ___/___
CLOCK PROGRAMMING
For example, to enter the date March 26, 2000 you would enter 20 (century), 00 (year), 03 (month), and 26 (day).
Section # Val ue
[557] Year ___/___/___/___ Month ___/___ Day ___/___
SECTION [553]: SERIAL AND PARALLEL PORT SETUP OPTIONS
Op ti on
OFF ON
[1]
Seri al p or t N Disabled N Enabled
[2]&[3]
N see table
N see table
N see table
N see table
[4]
Parallel port N Disabled N Enabled
[5]
Off-line status ignored (p ar al lel p or t onl y) N Disabled N Enabled
[6]
Paper empty status ignored (parallel port only) N Disabled N Enabled
[7]
Printer fault status igno re d (parallel por t onl y) N Disabled N Enabled
[8]
Printer busy status ignored (parallel port only) N Disabled N Enabled
Baud Rate Settin gs
[2] [3] APR-PRT1 APR3-PRT1
OF F O FF 1200 baud (default) 2400 baud (default)
ON OFF 2400 baud 9600 baud
OF F ON 9600 baud 19200 baud
ON ON 19200 baud 57600 baud