Spectra 1759EX - 20 - Programming Guide
4-PGM OUTPUT MODULES V2.0
Due to the APR3-PGM4’s Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), Digiplex or
DigiplexNE control panel. When connected to the bus, the APR3-PGM4 automatically detects which control panel it is
connected to and adjusts its internal communication parameters to function accordingly. Only one APR3-PGM4 can be
connected to each Spectra control panel.
Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and Digiplex. Modules with the
APR3- prefix are compatible with Spectra (versions 2.0 and higher), Digiplex and DigiplexNE.
Bold = Default Setting
PGM PROGRAMMING
Each PGM Deactivation event can be used as another activation event if their respective PGM timer (see sections [501] to
[504]) is programmed with a value other than 000. The APR3-PGM4 uses the same PGM events as the Spectra control
panel, please refer to “ Pr ogrammabl e Outputs” on page 9.
Section # Decimal Value (000-255) Description Default Value
[501] ___/___/___ (000 = follow deactivation event) PG M1 TIMER 5 sec.
[502] ___/___/___ (000 = follow deactivation event) PG M2 TIMER 5 sec.
[503] ___/___/___ (000 = follow deactivation event) PG M3 TIMER 5 sec.
[504] ___/___/___ (000 = follow deactivation event) PG M4 TIMER 5 sec.
Section # Event Group # Sub-Group # Partition #
[505] PGM1 Acti vation Event ___/___ ___/___ ___/___
[506] PGM1 Deactivation Event ___/___ ___/___ ___/___
[507] PGM2 Acti vation Event ___/___ ___/___ ___/___
[508] PGM2 Deactivation Event ___/___ ___/___ ___/___
[509] PGM3 Acti vation Event ___/___ ___/___ ___/___
[510] PGM3 Deactivation Event ___/___ ___/___ ___/___
[5 11] PGM4 Activati on Event ___/___ ___/___ ___/___
[512] PGM4 Deactivation Event ___/___ ___/___ ___/___
SECTION [500]: GENERAL OPTIONS
Opt ion
OFF ON
[1] PGM1 Time Base Selection N Seconds N Minutes
[2] PGM2 Time Base Selection N Seconds N Minutes
[3] PGM3 Time Base Selection N Seconds N Minutes
[4] PGM4 Time Base Selection N Seconds N Minutes
[5] Future use N N/A N N/A
[6] Future use N N/A N N/A
[7] Future use N N/A N N/A
[8] Future use N N/A N N/A