3. CC 355 – Data Sheet
6
Technical Data CC 355
Max. Cooling capacity (kW) * 40
Air flow evaporator (free-blowing, m³/h) 6300
Quantity of blowers 6
Max. outside temperature (°C)
60
Refrigerant (CFE-free) R-134a
Quantity of refrigerant (kg) ** 8,5
Compressor (cm³) 650
Weight (roof top unit, kg) 165
Dimensions (L x B x H in mm) 3480 x 1700 x 200
* evap. air in 40°C/ 46% r.h. ; ambient 35°C
** The quantity of refrigerant gas can vary according to the application and installation