6.6 UTILITY
With the program “Using”, it is possible to perform the following steps: gas recharge – calibration test-
measure unit – language – printer heading- service
Recharge GAS
See Chap. 6.0
CALIBRATION TEST
Choose “Calibration test” and confirm with key “ENTER”, on the display appears the weight of the gas in the
bottle and the coefficient of the cell. While putting the sample weight on the bottle, one can exactly read the
total weight from the display; the displays shows similarly the coefficient of the cell (for technical service).
MEASURE UNIT
It is possible to display the measuring unit in kg or pound;
Choose the “Measuring unit” and press the key “ENTER”;
Choose with the arrow keys the desired measuring unit and confirm with the key “ENTER”.
LANGUAGE
Confirm with „Enter“ and choose with the arrow keys the requested language (italian-english-french-german,
to confirm the choice press „Enter“
PRINTER HEADING (is for Printer version)
1) Select “printer heading” and push the ENTER key ;
2) The display shows “R1” (line no.);
3) Push the “ENTER” key, the first character will blink (or the first line);
4) With the arrow keys (+ and -) it is possible to select the requested character (numbers-symbols-capital
letters-small letters- space);
5) Confirm your choice with the “ENTER” key;
6) Next character will automatically blink;
7) Repeat the procedure from the step no. 4;
8) With the setting of the 24th character you will skip to the second line;
9) If you want to jump the line push “+” while any character or any line is blinking;
10) Set data as per the step no. 3;
11) Once set the 9th line push “ENTER” until the display will show again the message “printer heading”;
The heading is in this way memorized
TECHNICAL SERVICE (ONLY FOR THE TECHNICAL SERVICE)
Insert the pass word in order to perform the calibration of the scale.
7.0 HEATING INTERNAL BOTTLE
The heating of the bottle, with the following pressure rise, favours the charge of freon into the A/C plant in the
cool season of the year (with a bottle pressure < than 5-6 bar). The switch-on of the heating is being performed
automatically.
Printer (optional)