WARNINGS
TO MAINTAIN THE STATION WITH FULL EFFICIENCY IT IS NECESSARY TO PERFORM REGULAR MAINTENANCE
.
THE MANUFACTURER DECLINES ANY RESPONSIBILITIES FOR THE WARRANTY IN CASE OF NO COMPLIANCE
WITH THE MAINTENANCE PROCEDURES
.
ALL MAINTENANCE OPERATIONS HAVE TO BE PERFORMED AFTER DISCONNECTING THE STATION FROM THE
POWER SUPPLY
.
THE OPERATIONS THAT ARE NOT INCLUDED IN THE ORDINARY MAINTENANCE PROCEDURES MUST BE
CARRIED OUT BY SPECIALIZED AND TRAINED TECHNICIANS
.
Replace the dehydrating filter and the oil of the pump and clean the oil discharge filter periodically (according
to the use); however the display shows the message ATTENTION 9 - perform the maintenance of the
station” after 150 hours of functioning of the compressor, every time you switch on the station.
PUMP OIL
Replace the pump oil every 100/150 hours of functioning or at least every 1 year even if the station is
not always used.
It is highly recommended to replace the oil also when the presence of polluting substances can make
the oil dirty, in this case the mechanical parts of the pump may be seriously damaged. Use only
mineral oil for vacuum pumps type AV68I. The amount is approx. 300 gr.
OIL REFILL
Fill in the new oil from the cap B”, until you reach the level indicated by the apposite indicator
“C” fig. 11.
PUMP OIL REPLACEMENT
Discharge the oil from cap “A” fig. 11
Fill IN the new oil from cap “B”, until you reach the level indicated by the apposite indicator “C”.
WARNINGS
DO NOT DISPOSE OF THE OIL AS A NORMAL WASTE BUT AS A SPECIAL WASTE ACCORDING TO THE LAW IN
FORCE
.
CHAP. 7 - ORDINARY MAINTENANCE
Cod. Spare Oil
AV68I
Fig. 11
A
B
C